Middle-term results of threaded acetabular cups. High failure rates five years after surgery
- PMID: 9180310
- DOI: 10.1302/0301-620x.79b3.7273
Middle-term results of threaded acetabular cups. High failure rates five years after surgery
Abstract
We report our results using three different threaded acetabular components (Mecring A, Mecring B and Weill) in 715 hips with a follow-up of between one and ten years (median: 99.1, 56.5, 38.3 months, respectively). All cups were implanted with one type of cementless stem. The clinical results were good or acceptable in about 70% of the hips, but signs of loosening with radiolucency and/or migration were found in 10.1%. Radiological evidence of loosening did not correlate significantly with the clinical outcome. Pain was not a reliable indicator of loosening and its absence sometimes allowed severe osteolysis to develop. Twenty-five hips were revised (3.5%) for aseptic loosening of the acetabular component. Kaplan-Meier estimates of the cumulative rate of failure showed a rapid increase five years after the initial operation, but no significant correlation with gender, age or weight. The high rate of failure indicates that further use of these acetabular components cannot be recommended. Annual radiographs are required to assess osteolysis even if the patients are free from pain.
Similar articles
-
Total hip arthroplasty with a cemented, polished, collared femoral stem and a cementless acetabular component. A follow-up study at a minimum of ten years.J Bone Joint Surg Am. 2007 Jan;89(1):126-32. doi: 10.2106/JBJS.E.01214. J Bone Joint Surg Am. 2007. PMID: 17200319
-
Radiographic and clinical analysis of cementless acetabular fixation in total hip arthroplasty.Chin J Traumatol. 2005 Oct;8(5):263-8. Chin J Traumatol. 2005. PMID: 16176755
-
[Mid-term results of cementless ultima cups in primary total hip replacement].Acta Chir Orthop Traumatol Cech. 2008 Jun;75(3):205-11. Acta Chir Orthop Traumatol Cech. 2008. PMID: 18601819 Czech.
-
[Long-term results of the CLS acetabular cup in primary total hip replacement].Acta Chir Orthop Traumatol Cech. 2009 Apr;76(2):90-7. Acta Chir Orthop Traumatol Cech. 2009. PMID: 19439127 Czech.
-
Long-term fate of uncemented, threaded acetabular components with smooth surface treatment: minimum 10-year follow-up of two different designs.Arch Orthop Trauma Surg. 2004 Sep;124(7):469-75. doi: 10.1007/s00402-004-0709-y. Epub 2004 Jul 7. Arch Orthop Trauma Surg. 2004. PMID: 15241616
Cited by
-
Second-generation uncemented total hip arthroplasty: a minimum 20-year follow-up.Bone Jt Open. 2021 Jan 13;2(1):33-39. doi: 10.1302/2633-1462.21.BJO-2020-0157.R1. eCollection 2021 Jan. Bone Jt Open. 2021. PMID: 33537674 Free PMC article.
-
Current attitudes to total hip replacement in the younger patient: results of a national survey.Ann R Coll Surg Engl. 2000 Jan;82(1):33-8. Ann R Coll Surg Engl. 2000. PMID: 10700765 Free PMC article.
-
[Metal sensitivity in patients with joint replacement arthroplasties before and after surgery].Orthopade. 2008 Feb;37(2):102-10. doi: 10.1007/s00132-007-1186-0. Orthopade. 2008. PMID: 18210091 German.
-
Survival of the cementless Spotorno stem in the second decade.Clin Orthop Relat Res. 2009 Sep;467(9):2297-304. doi: 10.1007/s11999-009-0906-7. Epub 2009 Jun 6. Clin Orthop Relat Res. 2009. PMID: 19504161 Free PMC article.
-
Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.Int Orthop. 2010 Oct;34(7):943-8. doi: 10.1007/s00264-009-0844-8. Epub 2009 Jul 24. Int Orthop. 2010. PMID: 19629480 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources