[Reproducibility of the pattern electroretinogram]
- PMID: 9181839
- DOI: 10.1007/s003470050105
[Reproducibility of the pattern electroretinogram]
Abstract
The pattern ERG (PERG) is used as an indicator of retinal ganglion cell function. Up to now, reports on the reproducibility of the PERG have been contradictory. We investigated the reproducibility under the conditions of the forthcoming ISCEV guidelines for the PERG. We simultaneously recorded the PERG and VEP in 42 eyes of 21 subjects to phase-reversing checkerboard stimuli with DTL electrodes. Both transient (2 rps) and steady-state (16 rps) stimulation was employed. The check sizes were 0.4 degree, 0.8 degree and 16 degrees, the mean luminance 45 cd/m2, the contrast 98%, and the field size 32 degrees x 27 degrees. Measurements were repeated at the same time of day after 1 week. In addition, we compared two different electrode positions in 16 eyes: (1) across the cornea along the lower lid; and deep in the conjunctival sac. With position (1) the amplitudes were found to be higher by 20% than (2). We calculated the coefficient of variation (CV) of amplitude as a measure of reproducibility. CV was 7 +/- 1% for the steady-state PERG, 9 +/- 1% for the transient PERG, 12 +/- 2% for the steady-state VEP and 14 +/- 3% for the transient VEP. For the latency of the PERG, the intersession CV was found to be 1.5%. Amplitude reproducibility was somewhat higher under steady-state as compared to transient stimulation; we attribute this to the high noise rejection of the Fourier analysis. Altogether, the amplitude reproducibility of the PERG is somewhat higher than that of the VEP.
Similar articles
-
Retest variability and diurnal effects in the pattern electroretinogram.Doc Ophthalmol. 1996-1997;92(4):311-23. doi: 10.1007/BF02584085. Doc Ophthalmol. 1996. PMID: 9476598
-
Pattern electroretinogram to detect glaucoma: comparing the PERGLA and the PERG Ratio protocols.Doc Ophthalmol. 2013 Dec;127(3):227-38. doi: 10.1007/s10633-013-9412-z. Epub 2013 Oct 15. Doc Ophthalmol. 2013. PMID: 24126828
-
[Atrophy of the ganglion cells reduces pattern ERG not only in fine but also in coarse test patterns].Fortschr Ophthalmol. 1991;88(6):833-7. Fortschr Ophthalmol. 1991. PMID: 1794815 German.
-
ISCEV standard for clinical pattern electroretinography (PERG): 2012 update.Doc Ophthalmol. 2013 Feb;126(1):1-7. doi: 10.1007/s10633-012-9353-y. Epub 2012 Oct 17. Doc Ophthalmol. 2013. PMID: 23073702 Review.
-
Update on the pattern electroretinogram in glaucoma.Optom Vis Sci. 2008 Jun;85(6):386-95. doi: 10.1097/OPX.0b013e318177ebf3. Optom Vis Sci. 2008. PMID: 18521020 Review.
Cited by
-
Normative data for a user-friendly paradigm for pattern electroretinogram recording.Ophthalmology. 2004 Jan;111(1):161-8. doi: 10.1016/j.ophtha.2003.04.007. Ophthalmology. 2004. PMID: 14711729 Free PMC article.
-
Effects of DTL electrode position on the amplitude and implicit time of the electroretinogram.Doc Ophthalmol. 2020 Jun;140(3):201-209. doi: 10.1007/s10633-019-09733-3. Epub 2019 Nov 4. Doc Ophthalmol. 2020. PMID: 31686287 Free PMC article.
-
Evaluation of retinal ganglion cell function after intraocular pressure reduction measured by pattern electroretinogram in patients with primary open-angle glaucoma.Doc Ophthalmol. 2017 Apr;134(2):89-97. doi: 10.1007/s10633-017-9575-0. Epub 2017 Feb 7. Doc Ophthalmol. 2017. PMID: 28176172 Free PMC article.
-
The clinical value of the multi-channel PVEP and PERG in the diagnosis and management of the patient with pituitary adenoma: a case report.Doc Ophthalmol. 2018 Aug;137(1):37-45. doi: 10.1007/s10633-018-9647-9. Epub 2018 Jul 2. Doc Ophthalmol. 2018. PMID: 29968203 Free PMC article.
-
The importance of electrode position in visual electrophysiology.Doc Ophthalmol. 2017 Apr;134(2):129-134. doi: 10.1007/s10633-017-9579-9. Epub 2017 Feb 21. Doc Ophthalmol. 2017. PMID: 28224239
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources