Evaluation of an ultrasonic method applied to the measurement of blood coagulation time
- PMID: 9183807
- DOI: 10.1088/0967-3334/18/2/004
Evaluation of an ultrasonic method applied to the measurement of blood coagulation time
Abstract
Clinical assessment of the blood clotting mechanism is usually made by measuring the time necessary for a sample of plasma to clot. In this work a semi-automatic method for measuring coagulation time is evaluated. It employs ultrasound, at 2.7 MHz, for monitoring variations of the viscosity in a plasma sample undergoing coagulation. The evaluation is performed by comparing measurements obtained by two well-known methods, the manual tilt tube and the fibrometer, with those obtained using the ultrasonic method. A total of 330 plasma samples from individuals with normal and altered homeostatic process were analysed. The experimental protocol follows two standard tests: the prothrombin time (141 samples) and the activated partial thromboplastin time (189 samples). The agreement between the three different methods is estimated statistically and it is shown that all the three can be used interchangeably for clinical purposes.
Similar articles
-
Measurement of plasma clotting time using ultrasonic shear waves.Physiol Meas. 1994 Aug;15(3):309-16. doi: 10.1088/0967-3334/15/3/009. Physiol Meas. 1994. PMID: 7994209
-
Evaluation of the automated coagulation analyzer SYSMEX CA 6000.Thromb Res. 1999 Oct 1;96(1):65-71. doi: 10.1016/s0049-3848(99)00069-9. Thromb Res. 1999. PMID: 10554086
-
Evaluation of automatic and semiautomatic coagulation assay instruments.Clin Lab Haematol. 1980;2(3):215-26. doi: 10.1111/j.1365-2257.1980.tb00826.x. Clin Lab Haematol. 1980. PMID: 7428312
-
Comparison of prothrombin time and activated partial thromboplastin time on Dade Auto-FI and Bio-Quest Fibrometer.Res Commun Chem Pathol Pharmacol. 1978 Apr;20(1):165-73. Res Commun Chem Pathol Pharmacol. 1978. PMID: 663397
-
[Laboratory coagulation tests in patients treated by direct oral anticoagulants (DOACs)].Presse Med. 2015 Jul-Aug;44(7-8):772-8. doi: 10.1016/j.lpm.2015.06.004. Epub 2015 Aug 3. Presse Med. 2015. PMID: 26248706 Review. French.
Cited by
-
A novel ultrasonic method for evaluation of blood clotting parameters.J Med Ultrason (2001). 2018 Oct;45(4):545-553. doi: 10.1007/s10396-018-0874-1. Epub 2018 Mar 13. J Med Ultrason (2001). 2018. PMID: 29536280
-
ARFI ultrasound for in vivo hemostasis assessment postcardiac catheterization, part I: preclinical studies.Ultrason Imaging. 2009 Jul;31(3):153-8. doi: 10.1177/016173460903100301. Ultrason Imaging. 2009. PMID: 19771958 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources