Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1997 Apr;20(4):234-9.

Qualitative assessment of blood washing with the continuous autologous transfusion system (CATS)

Affiliations
  • PMID: 9195242
Clinical Trial

Qualitative assessment of blood washing with the continuous autologous transfusion system (CATS)

B H Walpoth et al. Int J Artif Organs. 1997 Apr.

Erratum in

  • Int J Artif Organs 1998 Mar;21(3):183

Abstract

A number of different blood-processing methods can be used at the end of cardiopulmonary bypass (CPB) to improve the quality of autologous blood. They include centrifugation, hemofiltration and cell-washing. They differ in processing time required, cost of disposables and the quality of the processed autologous blood product. The newly developed continuous auto-transfusion system (CATS: Fresenius AG, Bad Homburg) uses a continuous cell-washing method. In a prospective study, the oxygenator blood of 10 patients was processed at the end of cardiac surgery with CATS and the quality of autologous blood before and after processing was compared. The processing volumes and the time required were recorded. The concentrations and elimination rates of blood parameters and waste products such as activated coagulation and complement products were measured. At the end of CPB a mean volume of 1,010 +/- 174 ml diluted oxygenator blood was processed and concentrated to 310 +/- 88 ml in 11.0 +/- 2.2 mins. Cellular elements such as erythrocytes and leucocytes were mostly retained and their concentration showed a significant increase after processing (250% and 210% respectively; p < 0.01). Thus, the blood processing with CATS resulted in an excellent hemoconcentration (hematocrit 62 +/- 3 vs. 24 +/- 4% before processing) with a consistent reproducibility. On the other hand, the CATS concentrate showed a significant loss of autologous plasma proteins. Likewise, all water soluble elements such as waste products are significantly lower in concentration after processing and, if calculated by quantity, they show a high elimination rate (> 93%). In conclusion, the continuous autologous transfusion system permits an automated, rapid and continuous processing of autologous blood yielding a standardised high quality erythrocyte concentrate.

PubMed Disclaimer

Publication types

LinkOut - more resources