Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1997 May;76(5):405-10.
doi: 10.1136/adc.76.5.405.

Adrenal function and high dose inhaled corticosteroids for asthma

Affiliations
Clinical Trial

Adrenal function and high dose inhaled corticosteroids for asthma

P K Yiallouros et al. Arch Dis Child. 1997 May.

Abstract

Objective: To investigate effects on adrenal function of fluticasone, a recently released inhaled steroid preparation with lower systemic bioavailability than beclomethasone dipropionate.

Methods: 34 children on high doses (400-909 micrograms/m2/d) of inhaled beclomethasone dipropionate or budesonide were recruited into a double blind, crossover study investigating the effects on adrenal function of beclomethasone and fluticasone propionate, given using a standard spacer (Volumatic). The 24 hour excretion rates of total cortisol and cortisol metabolites were determined at baseline (after a two week run in), after six weeks treatment with an equal dose of beclomethasone, and after six weeks of treatment with half the dose of fluticasone, both given through a spacer device.

Results: The comparison of effects between fluticasone and beclomethasone during treatment periods, although favouring fluticasone in all measured variables, reached significance only after correction for urinary creatinine excretion (tetrahydrocortisol and 5 alpha-tetrahydrocortisol geometric means: 424 v 341 micrograms/m2/d). The baseline data showed adrenal suppression in the children taking beclomethasone (total cortisol geometric means: 975 v 1542 micrograms/d) and a dose related suppression in the children taking budesonide. Suppressed adrenal function in the children who were taking beclomethasone at baseline subsequently improved with fluticasone and beclomethasone during treatment periods.

Conclusions: Fluticasone is less likely to suppress adrenal function than beclomethasone at therapeutically equivalent doses. The baseline data also support the claim that spacer devices should be used for the administration of high doses of inhaled topical steroids.

PubMed Disclaimer

References

    1. Biometrics. 1972 Jun;28(2):577-84 - PubMed
    1. Am J Respir Crit Care Med. 1994 Sep;150(3):624-8 - PubMed
    1. Thorax. 1981 Jan;36(1):52-5 - PubMed
    1. Pediatrics. 1983 Jul;72(1):60-4 - PubMed
    1. Thorax. 1984 Dec;39(12):935-41 - PubMed

Publication types

MeSH terms