Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies
- PMID: 9205238
- DOI: 10.1148/radiology.204.1.9205238
Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies
Abstract
Purpose: To compare findings from first imaging follow-up mammography for breast lesions shown to be benign at stereotactic biopsy with 14-gauge automated needles or 14-gauge directional, vacuum-assisted probes.
Materials and methods: In 495 stereotactic breast biopsies, the mammographic appearance of the biopsy site or target lesion was evaluated at first imaging follow-up with a four-point scale (1 = progression of lesion or suspicious interval change [repeat biopsy], 2 = no clinically relevant change, 3 = interval decrease in size of lesion or number of microcalcifications, and 4 = no residual mammographic lesion). An automated needle was used in 363 biopsies and a directional, vacuum-assisted probe was used in 132 biopsies. Patient and lesion variables and time to first imaging follow-up were compared for the two techniques.
Results: No biopsy site or target lesion was assigned a score of 1 at first imaging follow-up with either technique. No lesion was referred for repeat biopsy because of the mammographic appearance at first imaging follow-up. First imaging follow-up was performed an average of 6.6 months for the directional, vacuum-assisted biopsies and 8.6 months for the automated needle biopsies (P < .0001). This difference reflected a difference in scheduling methods.
Conclusion: Directional, vacuum-assisted and automated needle breast biopsies produced no distortion or suspicious interval change at the biopsy site at the first follow-up mammographic examination.
Similar articles
-
Percutaneous removal of benign mammographic lesions: comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques.AJR Am J Roentgenol. 1998 Nov;171(5):1325-30. doi: 10.2214/ajr.171.5.9798873. AJR Am J Roentgenol. 1998. PMID: 9798873
-
Benign breast lesions: minimally invasive vacuum-assisted biopsy with 11-gauge needles patient acceptance and effect on follow-up imaging findings.Radiology. 2003 Mar;226(3):783-90. doi: 10.1148/radiol.2271011933. Radiology. 2003. PMID: 12616021
-
[Stereotactic 11-gauge directional vacuum-assisted breast biopsy: experience with 249 patients].J Radiol. 2002 Sep;83(9 Pt 1):1063-71. J Radiol. 2002. PMID: 12223915 French.
-
False-negative diagnoses at stereotactic vacuum-assisted needle breast biopsy: long-term follow-up of 1,280 lesions and review of the literature.AJR Am J Roentgenol. 2009 Feb;192(2):341-51. doi: 10.2214/AJR.08.1127. AJR Am J Roentgenol. 2009. PMID: 19155393 Review.
-
Role of stereotactic breast biopsy.Semin Surg Oncol. 1996 Sep-Oct;12(5):290-9. doi: 10.1002/(SICI)1098-2388(199609/10)12:5<290::AID-SSU3>3.0.CO;2-8. Semin Surg Oncol. 1996. PMID: 8873316 Review.
Cited by
-
Non-stereotactic method involving combination of ultrasound-guided wire localization and vacuum-assisted breast biopsy for microcalcification.Gland Surg. 2016 Jun;5(3):300-5. doi: 10.21037/gs.2015.12.02. Gland Surg. 2016. PMID: 27294037 Free PMC article.
-
The current role of vacuum assisted breast biopsy system in breast disease.J Breast Cancer. 2011 Mar;14(1):1-7. doi: 10.4048/jbc.2011.14.1.1. Epub 2011 Mar 31. J Breast Cancer. 2011. PMID: 21847387 Free PMC article.
-
Charcoal granuloma mimicking breast cancer: an emerging diagnosis.Acta Radiol Open. 2018 Dec 6;7(12):2058460118815726. doi: 10.1177/2058460118815726. eCollection 2018 Dec. Acta Radiol Open. 2018. PMID: 30619625 Free PMC article.
-
Vacuum-assisted breast biopsy for breast cancer.Gland Surg. 2014 May;3(2):120-7. doi: 10.3978/j.issn.2227-684X.2014.02.03. Gland Surg. 2014. PMID: 25083505 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical