Screening blood spots for inborn errors of metabolism by electrospray tandem mass spectrometry with a microplate batch process and a computer algorithm for automated flagging of abnormal profiles
- PMID: 9216448
Screening blood spots for inborn errors of metabolism by electrospray tandem mass spectrometry with a microplate batch process and a computer algorithm for automated flagging of abnormal profiles
Abstract
Metabolic profiling of amino acids and acylcarnitines from blood spots by automated electrospray tandem mass spectrometry (ESI-MS/MS) is a powerful diagnostic tool for inborn errors of metabolism. New approaches to sample preparation and data interpretation have helped establish the methodology as a robust, high-throughput neonatal screening method. We introduce an efficient 96-well-microplate batch process for blood-spot sample preparation, with which we can obtain high-quality profiles from 500-1000 samples per day per instrument. A computer-assisted metabolic profiling algorithm automatically flags abnormal profiles. We selected diagnostic parameters for the algorithm by comparing profiles from patients with known metabolic disorders and those from normal newborns. Reference range and cutoff values for the diagnostic parameters were established by measuring either metabolite concentrations or peak ratios of certain metabolite pairs. Rigorous testing of the algorithm demonstrates its outstanding clinical sensitivity in flagging abnormal profiles and its high cumulative specificity.
Similar articles
-
Expanded newborn screening of inborn errors of metabolism by capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS).Methods Mol Biol. 2013;919:43-56. doi: 10.1007/978-1-62703-029-8_5. Methods Mol Biol. 2013. PMID: 22976089
-
Diagnosis of inborn errors of metabolism from blood spots by acylcarnitines and amino acids profiling using automated electrospray tandem mass spectrometry.Pediatr Res. 1995 Sep;38(3):324-31. doi: 10.1203/00006450-199509000-00009. Pediatr Res. 1995. PMID: 7494654
-
Stability of acylcarnitines and free carnitine in dried blood samples: implications for retrospective diagnosis of inborn errors of metabolism and neonatal screening for carnitine transporter deficiency.Anal Chem. 2009 May 1;81(9):3571-5. doi: 10.1021/ac8022235. Anal Chem. 2009. PMID: 19323528
-
Application of electrospray tandem mass spectrometry to neonatal screening.Semin Perinatol. 1999 Apr;23(2):183-93. doi: 10.1016/s0146-0005(99)80050-0. Semin Perinatol. 1999. PMID: 10331469 Review.
-
A biochemical perspective on the use of tandem mass spectrometry for newborn screening and clinical testing.Clin Biochem. 2005 Apr;38(4):296-309. doi: 10.1016/j.clinbiochem.2005.01.017. Clin Biochem. 2005. PMID: 15766731 Review.
Cited by
-
Pseudo-glutarylcarnitinaemia in medium-chain acyl-CoA dehydrogenase deficiency detected by tandem mass spectrometry newborn screening.J Inherit Metab Dis. 2004;27(4):465-71. doi: 10.1023/B:BOLI.0000037343.90450.8d. J Inherit Metab Dis. 2004. PMID: 15303003
-
Screening of newborn infants for cholestatic hepatobiliary disease with tandem mass spectrometry.BMJ. 1999 Aug 21;319(7208):471-7. doi: 10.1136/bmj.319.7208.471. BMJ. 1999. PMID: 10454398 Free PMC article.
-
Rapid Multiplexed Proteomic Screening for Primary Immunodeficiency Disorders From Dried Blood Spots.Front Immunol. 2018 Dec 4;9:2756. doi: 10.3389/fimmu.2018.02756. eCollection 2018. Front Immunol. 2018. PMID: 30564228 Free PMC article.
-
Genetics and genomic medicine in Saudi Arabia.Mol Genet Genomic Med. 2014 Sep;2(5):369-78. doi: 10.1002/mgg3.97. Epub 2014 Jul 30. Mol Genet Genomic Med. 2014. PMID: 25333061 Free PMC article. No abstract available.
-
Screening newborns for metabolic disorders based on targeted metabolomics using tandem mass spectrometry.Ann Pediatr Endocrinol Metab. 2015 Sep;20(3):119-24. doi: 10.6065/apem.2015.20.3.119. Epub 2015 Sep 30. Ann Pediatr Endocrinol Metab. 2015. PMID: 26512346 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical