[Assessment of the accuracy of position in breast irradiation with isocentric technique using an electronic system to acquire portal images]
- PMID: 9221419
[Assessment of the accuracy of position in breast irradiation with isocentric technique using an electronic system to acquire portal images]
Abstract
This study investigated the accuracy of daily patient positioning in an isocentric set-up for breast irradiation. This was achieved through the assessment of both systematic and random errors measured as discrepancies between reference simulation images and portal images obtained with an on-line electronic portal imaging device (EPID). To this end, 10 portal images for each of the tangential fields were obtained in 12 consecutive patients and the images were compared to reference simulation films with dedicated software tools provided with the EPID. The discrepancies measured for each set of images were analyzed statistically. Most variations in each series both in terms of cranio-caudal and of lateral displacement appeared to be random, with mean standard deviations of 2.3 and 2.8 mm, respectively. Such variations between reference fields and portal images tend to counteract one another and do not usually play a significant role in the overall accuracy of patient set-up. In some cases, however, the distribution of the variations occurred in a well-defined pattern indicating a systematic error in patient positioning. This study shows that our set-up technique for breast irradiation is relatively accurate and reproducible, and most of the observed errors were below the 5 mm cut-off level, but it stresses the need of accurate quality assurance programs in radiotherapy. Electronic portal imaging devices are excellent tools for fast portal image acquisition, and permit the accurate assessment of discrepancies with respect to reference images.
Similar articles
-
Verification of set-up deviations in patients with breast cancer using portal imaging in clinical practice.Strahlenther Onkol. 1998 Oct;174 Suppl 2:36-9. Strahlenther Onkol. 1998. PMID: 9810336
-
Evaluation of set-up deviations during the irradiation of patients suffering from breast cancer treated with two different techniques.Radiother Oncol. 2005 Apr;75(1):22-7. doi: 10.1016/j.radonc.2005.02.004. Epub 2005 Apr 18. Radiother Oncol. 2005. PMID: 15878097 Clinical Trial.
-
Treatment accuracy of fractionated stereotactic radiotherapy.Radiother Oncol. 2005 Jan;74(1):53-9. doi: 10.1016/j.radonc.2004.06.008. Radiother Oncol. 2005. PMID: 15683670 Clinical Trial.
-
[Routine use of electronic portal imaging. Positioning verification in 922 successive pelvic fields].Bull Cancer Radiother. 1995;82(1):20-7. Bull Cancer Radiother. 1995. PMID: 7702935 Review. French.
-
Accuracy in tangential breast treatment set-up: a portal imaging study.Radiother Oncol. 1991 Dec;22(4):317-22. doi: 10.1016/0167-8140(91)90171-c. Radiother Oncol. 1991. PMID: 1792329 Review.
Cited by
-
Evaluation of methods for opto-electronic body surface sensing applied to patient position control in breast radiation therapy.Med Biol Eng Comput. 2003 Nov;41(6):679-88. doi: 10.1007/BF02349976. Med Biol Eng Comput. 2003. PMID: 14686594
Publication types
MeSH terms
LinkOut - more resources
Medical