Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Aug;158(2):505-8; discussion 508-9.

Prevalence and predictors of a positive repeat transrectal ultrasound guided needle biopsy of the prostate

Affiliations
  • PMID: 9224334

Prevalence and predictors of a positive repeat transrectal ultrasound guided needle biopsy of the prostate

N E Fleshner et al. J Urol. 1997 Aug.

Abstract

Purpose: We determined the prevalence of and risk factors for carcinoma in patients with 1 previously negative prostate biopsy.

Materials and methods: Transrectal ultrasound guided prostate needle biopsies were repeated in 130 men. Risk factors analyzed included age, pathological result of initial biopsy, inter-biopsy interval, prostate specific antigen (PSA), PSA density, PSA velocity, digital rectal examination, abnormal transrectal ultrasound and family history of prostate cancer.

Results: A total of 39 patients (30%) had positive biopsies for cancer. Univariate analysis revealed that PSA more than 20 ng./ml. and abnormal transrectal ultrasound were more frequent in men with positive second biopsies. Using multivariate logistic regression analysis only PSA more than 20 ng./ml. was a significant risk factor (adjusted odds ratio 4.48, 95% confidence interval 1.02 to 20.1). We determined the incidence of carcinoma in patients who represent the lowest risk group as defined by PSA less than 10 ng./ml., PSA density less than 0.15 mg./ml./cm.3, PSA velocity less than 0.75, ng./ml. per year, no prostatic intraepithelial neoplasia plus negative transrectal ultrasound, digital rectal examination and family history. Of 21 patients who fit this cohort 5 (23.8%) had carcinoma on repeat biopsy.

Conclusions: A significant false-negative rate for initial transrectal ultrasound guided prostate biopsies exists. Baseline risk in lowest risk patients is sufficiently high such that one cannot define a subset of patients for whom repeat biopsy is unnecessary. We recommend repeat biopsy in all patients who meet the criteria for a transrectal ultrasound guided biopsy and in whom the initial biopsy is negative.

PubMed Disclaimer

Publication types