Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997;76(2):220-5.
doi: 10.1038/bjc.1997.365.

Comparison of radiobiological effective depths in 65-MeV modulated proton beams

Affiliations
Free PMC article

Comparison of radiobiological effective depths in 65-MeV modulated proton beams

J T Tang et al. Br J Cancer. 1997.
Free PMC article

Abstract

To assess the achievement of uniformity of radiobiological effectiveness at different depths in the proton spread-out Bragg peak (SOBP), Chinese hamster ovary (CHO) cells were exposed to 65-MeV modulated proton beams at the Research Center for Nuclear Physics (RCNP) of Osaka University. We selected four different irradiation positions: 2 mm depth, corresponding to the entrance, and 10, 18 and 23 mm depths, corresponding to different positions in the SOBP. Cell survival curves were generated with the in vitro colony formation method and fitted to the linear-quadratic model. With 137Cs gamma-rays as the reference irradiation, the relative biological effectiveness (RBE) values for a surviving fraction (SF) level of 0.1 are 1.05, 1.10, 1.12 and 1.19 for depths of 2, 10, 18 and 23 mm respectively. A significant difference was found between the survival curves at 10 and 23 mm (P < 0.05), but not between 18 and 10 mm or between 18 and 23 mm. There was a significant dependence of RBE on depths in modulated proton beams at the 0.1 surviving fraction level (P < 0.05). Moreover, the rise of RBEs significantly depended on increasing SF level or decreased approximately in correspondence with irradiation dose (P = 0.0001). To maintain uniformity of radiobiological effectiveness for the target volume, careful attention should be paid to the influence of depth of beam and irradiation dose.

PubMed Disclaimer

References

    1. Cancer. 1975 Jun;35(6):1664-77 - PubMed
    1. Radiat Res. 1996 Apr;145(4):391-407 - PubMed
    1. Int J Radiat Oncol Biol Phys. 1980 Sep;6(9):1187-93 - PubMed
    1. Radiother Oncol. 1987 Mar;8(3):237-52 - PubMed
    1. Int J Radiat Biol. 1989 Jan;55(1):93-104 - PubMed

Publication types