Development of a new outcomes instrument for conductive hearing loss
- PMID: 9233479
Development of a new outcomes instrument for conductive hearing loss
Abstract
Objective: The objective was to design and validate a disease-specific outcomes instrument for use in conductive hearing loss (CHL).
Study design: The study was a retrospective survey of 47 patients recently treated for CHL with either a hearing aid or surgery. Patients were tested with the newly designed instrument (the Hearing Satisfaction Scale [HSS]), previously validated hearing-specific instruments, and a generic quality-of-life instrument.
Setting: The study was performed in an academic tertiary referral center.
Main outcome measures: These included test-retest reliability, internal consistency reliability, content validity, criterion validity, and construct validity of the HSS.
Results: Test-retest reliability (r = 0.72, p < 0.001) and internal consistency reliability were adequate (Cronbach's alpha was 0.83 and 0.74 for the two subscales of the HSS). Criterion validity for individual items was adequate (r = 0.45, p = 0.02) using audiometric data as the criterion standard. Construct validity was also high using results from other instruments; both convergent and divergent validity of the HSS was demonstrated. In addition, the HSS demonstrated the ability to differentially discriminate between subgroups when grouped by level of hearing loss.
Conclusions: The HSS is a valid and reliable instrument for use in outcomes research on conductive hearing loss.
Similar articles
-
Outcomes and patient-based hearing status in conductive hearing loss.Laryngoscope. 2001 Nov;111(11 Pt 2 Suppl 98):1-21. doi: 10.1002/lary.5541111401. Laryngoscope. 2001. PMID: 11802001 Review.
-
The development of a questionnaire to measure the severity of symptoms and the quality of life before and after surgery for stress incontinence.BJOG. 2003 Nov;110(11):983-8. BJOG. 2003. PMID: 14592582
-
Development and validation of the effectiveness of [corrected] auditory rehabilitation scale.Arch Otolaryngol Head Neck Surg. 2005 Oct;131(10):851-6. doi: 10.1001/archotol.131.10.851. Arch Otolaryngol Head Neck Surg. 2005. PMID: 16230585
-
Validation of a voice prosthesis questionnaire to assess valved speech and its related issues in patients following total laryngectomy.Clin Otolaryngol. 2006 Oct;31(5):404-10. doi: 10.1111/j.1749-4486.2006.01289.x. Clin Otolaryngol. 2006. PMID: 17014450
-
Validation of the Chinese version of the satisfaction with the nursing home instrument.J Clin Nurs. 2006 Dec;15(12):1574-82. doi: 10.1111/j.1365-2702.2005.01507.x. J Clin Nurs. 2006. PMID: 17118080
Cited by
-
[State of the art of quality-of-life measurement in patients with chronic otitis media and conductive hearing loss].HNO. 2018 Aug;66(8):578-589. doi: 10.1007/s00106-018-0524-3. HNO. 2018. PMID: 29915938 Review. German.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources