Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1997 Jun;11(6):1086-92.
doi: 10.1016/s1010-7940(97)01214-1.

ITA versus SVG: a comparison of instantaneous pressure and flow dynamics during competitive flow

Affiliations
Comparative Study

ITA versus SVG: a comparison of instantaneous pressure and flow dynamics during competitive flow

S Pagni et al. Eur J Cardiothorac Surg. 1997 Jun.

Abstract

Objective: Competitive flow from patent native coronary vessels is implicated in the failure of internal thoracic artery (ITA) grafts, but it is not thought to affect saphenous vein graft (SVG) patency. This study examines instantaneous pressure and flow dynamics in left ITA and SVG grafts in competition with a patent left anterior descending (LAD) artery.

Methods: SVG (3.0-4.0 mm) and ITA (1.5-2.0 mm) to proximal LAD (2.5-3.0 mm) coronary bypass was performed in 10 mongrel dogs. Flow and pressure were measured in the occluded (No Competition) and opened (Competition) ITA, SVG and LAD.

Results: The ITA and SVG, when each was the sole inflow to the LAD, provided similar flow as the native LAD. During competitive flow, total LAD flow was preserved and flow in the ITA and SVG were reduced (8.20 +/- 1.25 and 10.00 +/- 1.73 ml/min; P < 0.005). SVG diastolic flow was reduced to 11.52 +/- 2.17 ml min (55.5%); P < 0.003. Flow in the SVG remained predominantly antegrade. In contrast, ITA diastolic flow was reduced more drastically, to 5.37 +/- 1.25 ml/min (80.7%); P < 0.0001. When the ITA was the only inflow to the LAD, there was delay in the LAD pressure wave. This delay disappears during competition due to the large, systolic retrograde flow up the ITA.

Conclusion: The ITA, compared to the SVG, is a longer and narrower conduit with lower levels of flow during competition. Due to a delay in the pressure wave, the ITA flow is retrograde during early systole. Low levels of flow, with a markedly decreased diastolic phase, and the oscillating pattern in systole (retrograde/antegrade) may be poorly tolerated by the ITA endothelium and lead to graft deterioration.

PubMed Disclaimer

Publication types