Expanded polytetrafluoroethylene patches used in the intraperitoneal or extraperitoneal position for repair of incisional hernias of the anterolateral abdominal wall
- PMID: 9240945
- DOI: 10.1016/S0002-9610(97)00047-0
Expanded polytetrafluoroethylene patches used in the intraperitoneal or extraperitoneal position for repair of incisional hernias of the anterolateral abdominal wall
Abstract
Background: Few large studies of the use of expanded polytetrafluoroethylene (ePTFE) in incisional hernia repairs have been done. We performed such a study of ePTFE patches implanted extraperitoneally or intraperitoneally.
Methods: The records of all patients in whom an ePTFE patch was used to repair an incisional hernia in 1987 to 1994 were reviewed retrospectively.
Results: An ePTFE patch was implanted in 158 patients, extraperitoneally in 98 and intraperitoneally in 60. There were no perioperative deaths. Serious postoperative complications, including 3 cases of sepsis (intraperitoneally placed patch), occurred in 6 patients (4%). With a mean follow-up of 37 months (range 12 to 90), there were 2 cases of late sepsis (with an extraperitoneal patch) and 6 recurrences (4 with an intraperitoneal patch).
Conclusions: The ePTFE prostheses used in incisional hernia repair are well tolerated in the intraperitoneal position. Their effectiveness in the extraperitoneal position may be comparable to that of mesh but with a lower rate of sepsis.
Comment in
-
Expanded polytetrafluoro-ethylene patches.Am J Surg. 1998 Apr;175(4):342. Am J Surg. 1998. PMID: 9568670 No abstract available.