Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Aug;124(2):158-67.
doi: 10.1016/s0002-9394(14)70780-9.

Analysis of visual dysfunctions in HIV-positive patients without retinitis

Affiliations

Analysis of visual dysfunctions in HIV-positive patients without retinitis

A J Mueller et al. Am J Ophthalmol. 1997 Aug.

Abstract

Purpose: To investigate visual dysfunctions in ophthalmoscopically normal human immunodeficiency virus (HIV)-positive patients and to correlate the results to the stage of HIV disease and neuropsychological status.

Methods: Fifty-one randomly selected eyes (26 right, 25 left) of 51 HIV-positive patients with visual acuity measurements of 20/20 or better and no ophthalmoscopically detectable disorders were prospectively examined using achromatic and short-wavelength automated perimetry, color vision testing, and contrast sensitivity testing. CD4+ T-lymphocyte count, presence of systemic infection, hemoglobin, hematocrit, serum beta 2-microglobulin levels, and results of neuropsychological testing were also analyzed.

Results: On achromatic automated perimetry, 21.6% (11/51) of patients performed abnormally according to the mean defect and 27.5% (14/51) according to the Glaucoma Hemifield Test; 29.4% (15/51) performed abnormally on short-wave-length automated perimetry according to the mean defect and 23.5% (12/51) according to the Glaucoma Hemifield Test. On contrast sensitivity, 5.9% (3/51) of patients performed abnormally in the 1.5-cycles per degree (cpd) line, 2.0% (2/51) in the 3-cpd line, 23.5% (12/51) in the 6-cpd line, 25.5% (13/51) in the 12-cpd line, and 33.3% (17/51) in the 18-cpd line. On the Farnsworth-Munsell 100-hue test, 29.4% (15/51) of patients performed abnormally. After correction for multiple correlations, two statistically significant correlations were found: sum of log contrast sensitivity with achromatic automated perimetry and sum of log contrast sensitivity with the Farnsworth-Munsell 100-hue test.

Conclusions: A significant percentage of HIV-positive patients with visual acuity of 20/20 or better and no ophthalmologic evidence of retinitis performed abnormally on visual psychophysical tests. The severity of visual dysfunction was not correlated with the stage of HIV infection or the degree of neuropsychological dysfunction.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources