Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1997 Apr-May;51(3):147-53.

Ease of handling and clinical efficacy of fluticasone propionate Accuhaler/Diskus inhaler compared with the Turbohaler inhaler in paediatric patients. UK Study Group

Affiliations
  • PMID: 9293055
Clinical Trial

Ease of handling and clinical efficacy of fluticasone propionate Accuhaler/Diskus inhaler compared with the Turbohaler inhaler in paediatric patients. UK Study Group

J Williams et al. Br J Clin Pract. 1997 Apr-May.

Abstract

A total of 323 children aged 4-11 years who were receiving, or had symptoms indicating a clinical requirement for, inhaled corticosteroid at a daily dose of 400 micrograms budesonide (BUD) or beclomethasone dipropionate (BDP), or 200 micrograms fluticasone propionate (FP), were randomised into this multicentre, open-label, parallel group study. Patients received either FP 100 micrograms b.d. administered via the Accuhaler/Diskus inhaler (n = 159) or BUD 200 micrograms b.d. administered via a Turbohaler inhaler (n = 164) for four weeks and recorded daily their morning and evening peak expiratory flow (PEF), asthma symptoms and use of relief medication. Device handling was assessed by a questionnaire, with responses recorded on three- or five-point ordinal scales. The primary efficacy parameter was mean percent predicted morning PEF. The device handling results showed the Accuhaler/Diskus inhaler was rated more favourably than the Turbohaler inhaler in terms of ease of correct inhaler use, ease of telling how many doses were left, ease of knowing whether a dose had been inhaled and overall liking of the device. More patients in the Accuhaler/Diskus group (85%) than in the Turbohaler group (58%) said they would be happy to receive the same device again, while 8% and 25% respectively said they would not be happy to be given it again. In addition, the change from baseline to week 4 of treatment in mean percent predicted morning PEF was greater in the FP Accuhaler/Diskus group, indicating that FP 200 micrograms daily via Accuhaler/Diskus inhaler is at least as clinically effective as BUD 400 micrograms daily via the Turbohaler inhaler.

PubMed Disclaimer