Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Sep;4(5):598-603.
doi: 10.1128/cdli.4.5.598-603.1997.

Synthetic-peptide-based enzyme-linked immunosorbent assay for screening human serum or plasma for antibodies to human immunodeficiency virus type 1 and type 2

Affiliations

Synthetic-peptide-based enzyme-linked immunosorbent assay for screening human serum or plasma for antibodies to human immunodeficiency virus type 1 and type 2

L Gonzalez et al. Clin Diagn Lab Immunol. 1997 Sep.

Abstract

A synthetic-peptide-based enzyme-linked immunosorbent assay (EIA) capable of screening for antibodies to both human immunodeficiency virus type 1 (HIV-1) and HIV-2 has been developed for use in blood banks and diagnostic laboratories. Microtiter wells are coated with two synthetic peptides, one corresponding to the highly conserved envelope region of HIV-1 and another corresponding to the conserved envelope region of HIV-2. Overall, sensitivity was 100% in 303 individuals diagnosed with AIDS and 96 individuals diagnosed with AIDS-related complex, 14.8% in a study of 500 high-risk group members, 99.9% in 600 EIA repeatedly reactive (RR)-HIV-1 Western blot (WB)-positive repository specimens, and 100% for 222 geographically diverse HIV-1 specimens and 216 confirmed HIV-2-positive specimens evaluated. The specificity was determined to be 99.72% for a total of 13,004 serum and plasma samples from random volunteer donors evaluated across five blood banks. Forty donors who were found to be EIA RR-WB indeterminate but nonreactive on the United Biomedical, Inc., test (UBI HIV 1/2 EIA) were prospectively followed as an additional measure of specificity. None of the 40 low-risk cases evolved into a positive WB pattern at follow-up. The sensitivity and specificity of this new assay are comparable to those of other Food and Drug Administration-licensed HIV-1 and HIV-1-HIV-2 assays that are currently available in the United States. The UBI HIV 1/2 EIA affords laboratories another choice in the detection of antibodies for HIV-1 and HIV-2 with a test based on an alternative antigen format.

PubMed Disclaimer

References

    1. Science. 1985 Apr 5;228(4695):93-6 - PubMed
    1. Lancet. 1985 May 25;1(8439):1222-3 - PubMed
    1. Lancet. 1986 Nov 29;2(8518):1233-6 - PubMed
    1. J Virol. 1987 Feb;61(2):629-32 - PubMed
    1. Lancet. 1987 May 30;1(8544):1249-53 - PubMed

LinkOut - more resources