We have developed a software suite that automatically selects, analyses, quantitates and displays all the key image data in a myocardial perfusion SPECT study.
Methods: The files automatically selected (upon specification of the patient name) are rest and stress projections, rest and stress short axis and gated short axis files, and all 'snapshot' files. The projection data sets are presented in cine mode for evaluation of patient motion, while the lung/heart ratio at rest and stress is calculated from regions of interest (ROIs) that are automatically derived and overlayed on the LAO 45 images. Left ventricular (LV) cavity volumes at rest and stress are calculated from the short axis data sets, and the related transient ischemic dilation (TID) ratio derived and displayed. Quantitative measurements of global (ejection fraction) and regional function parameters are performed from the gated short axis dataset. All algorithms use the C++, X-Windows and OSF-Motif standards. The overall suite executes in less than 1 minute on a SunSPARC5 with 32 Mb of RAM and no proprietary hardware.
Results: The software was validated on 144 patients (118 rest 201T1/post-stress 99mTc-sestamibi, 18 post-stress 99mTC-sestamibi, 8 rest 201Tl) acquired on a 90 degrees dual detector (ADAC Vertex, 91 patients) and a triple detector camera (Picker Prism 3000, 53 patients). Overall, the individual algorithms for the analysis of projection, short axis and gated short axis images were successful in 622/660 (94.2%) of the images. In 80.5% of the patients (73/91 + 43/53) all algorithms executed successfully, without significant difference in success rates for 201Tl versus 99mTc-sestamibi images.
Conclusion: Our automated approach to myocardial perfusion SPECT analysis and review is highly successful, intrinsically reproducible, and can produce time and cost savings while improving accuracy in a clinical or teleradiology-type environment.
Similar articles
-
A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility.J Nucl Med. 2000 Apr;41(4):712-9. J Nucl Med. 2000. PMID: 10768574
-
Operator-less processing of myocardial perfusion SPECT studies.J Nucl Med. 1995 Nov;36(11):2127-32. J Nucl Med. 1995. PMID: 7472609
-
Effect of the number of projections collected on quantitative perfusion and left ventricular ejection fraction measurements from gated myocardial perfusion single-photon emission computed tomographic images.J Nucl Cardiol. 1996 Sep-Oct;3(5):395-402. doi: 10.1016/s1071-3581(96)90074-4. J Nucl Cardiol. 1996. PMID: 8902671
-
Automated quantification of myocardial ischemia and wall motion defects by use of cardiac SPECT polar mapping and 4-dimensional surface rendering.J Nucl Med Technol. 2006 Mar;34(1):3-17. J Nucl Med Technol. 2006. PMID: 16517964 Review.
-
[Role of perfusion myocardial scintigraphy with gated SPECT technique in the diagnostic and prognostic evaluation of patients with chronic coronary disease].Ital Heart J Suppl. 2002 Mar;3(3):309-18. Ital Heart J Suppl. 2002. PMID: 12040846 Review. Italian.
Cited by
-
Validation of threshold method for myocardial control database by use of clinical data.Radiol Phys Technol. 2014 Jul;7(2):340-51. doi: 10.1007/s12194-014-0271-4. Epub 2014 Jun 6. Radiol Phys Technol. 2014. PMID: 24903494
-
Count density curves for gated SPECT myocardial perfusion imaging studies: An overview of technical considerations, patterns in various arrhythmia-related artifacts, and a technologist's guide for curve plotting.J Nucl Cardiol. 2018 Aug;25(4):1156-1163. doi: 10.1007/s12350-018-1277-9. Epub 2018 Apr 13. J Nucl Cardiol. 2018. PMID: 29654446 Review. No abstract available.
-
Variation in heart rate influences the assessment of transient ischemic dilation in myocardial perfusion scintigraphy.BMC Nucl Med. 2007 Jan 11;7:1. doi: 10.1186/1471-2385-7-1. BMC Nucl Med. 2007. PMID: 17217538 Free PMC article.
-
SPECT myocardial perfusion imaging as an adjunct to coronary calcium score for the detection of hemodynamically significant coronary artery stenosis.BMC Cardiovasc Disord. 2012 Dec 4;12:116. doi: 10.1186/1471-2261-12-116. BMC Cardiovasc Disord. 2012. PMID: 23206557 Free PMC article.
-
Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods.J Nucl Cardiol. 2001 Nov-Dec;8(6):645-51. doi: 10.1067/mnc.2001.117173. J Nucl Cardiol. 2001. PMID: 11725260 Clinical Trial.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous