A prospective randomized trial of preoperative "optimization" of cardiac function in patients undergoing elective peripheral vascular surgery
- PMID: 9308617
- DOI: 10.1016/s0039-6060(97)90132-x
A prospective randomized trial of preoperative "optimization" of cardiac function in patients undergoing elective peripheral vascular surgery
Abstract
Background: Previous investigations have suggested that preoperative invasive hemodynamic monitoring with "optimization" of cardiovascular function may favorably affect the outcome among patients undergoing peripheral vascular surgery. The purpose of this study was to evaluate the effect of preoperative optimization of hemodynamic parameters on outcome in patients undergoing aortic reconstruction (AR) or limb salvage procedures (LSP) in a randomized, prospective clinical trial.
Methods: All 72 patients who consented to participate in this study were admitted to the intensive care unit at least 12 hours before operation for placement of a pulmonary artery catheter (PAC). Patients who were randomized to the treatment group (n = 32) were "optimized" by adjusting their hemoglobin concentration, oxygen saturation (SaO2), cardiac output, or afterload until the mixed venous O2 saturation (SvO2) was at least 65%. The control group (n = 40) underwent placement of a PAC and had oxygen transport parameters measured without any attempt to optimize SvO2.
Results: There were no significant differences between the treatment and control groups with respect to age, gender, type of operation, initial Acute Physiology and Chronic Health Evaluation (APACHE) II score, SvO2, pulmonary artery occlusion pressure, or cardiac index. All treatment patients achieved an SvO2 of at least 65% before operation. Comparing the treatment and control groups, postoperative cardiovascular complications occurred in 25% versus 27%, intraoperative complications in 28% versus 20%, and death in 9% versus 5%, respectively. None of these differences was statistically significant as a whole or within the subgroups undergoing AR or LSP.
Conclusions: These data suggest that preoperative optimization of cardiovascular function by using achievement of SvO2 above 65% as the end point does not result in any reduction of intraoperative or perioperative cardiac complications in patients undergoing PVS. Further studies with alternative assessments and manipulation of different cardiopulmonary parameters may yield additional information.
Comment in
-
Preoperative optimization of cardiac function using SvO2.Surgery. 1998 Jun;123(6):719-20. doi: 10.1016/s0039-6060(98)70215-6. Surgery. 1998. PMID: 9626327 No abstract available.
Similar articles
-
Preoperative intensive care unit admission and hemodynamic monitoring in patients scheduled for major elective noncardiac surgery: a retrospective review of 95 patients.J Cardiothorac Vasc Anesth. 1998 Feb;12(1):3-9. doi: 10.1016/s1053-0770(98)90047-7. J Cardiothorac Vasc Anesth. 1998. PMID: 9509349
-
Predictive factors for usefulness of fiberoptic pulmonary artery catheter for continuous oxygen saturation in mixed venous blood monitoring in cardiac surgery.Anesth Analg. 1997 Jul;85(1):2-10. doi: 10.1097/00000539-199707000-00002. Anesth Analg. 1997. PMID: 9212114
-
Preoperative optimization of cardiovascular hemodynamics improves outcome in peripheral vascular surgery. A prospective, randomized clinical trial.Ann Surg. 1991 Sep;214(3):289-97; discussion 298-9. doi: 10.1097/00000658-199109000-00011. Ann Surg. 1991. PMID: 1929610 Free PMC article. Clinical Trial.
-
[Continuous monitoring of mixed venous oxygen saturation in anesthesia in pulmonary surgery].Ann Fr Anesth Reanim. 1989;8(6):682-7. doi: 10.1016/s0750-7658(89)80191-1. Ann Fr Anesth Reanim. 1989. PMID: 2699175 Review. French.
-
[Continuous monitoring of mixed venous blood oxygen saturation].Ann Fr Anesth Reanim. 1993;12(4):393-408. doi: 10.1016/s0750-7658(05)80107-8. Ann Fr Anesth Reanim. 1993. PMID: 8273928 Review. French.
Cited by
-
[Pulmonary artery catheter in anaesthesia and intensive care medicine].Anaesthesist. 2007 Mar;56(3):273-5; author reply 276, 278-80. doi: 10.1007/s00101-007-1139-3. Anaesthesist. 2007. PMID: 17333034 German. No abstract available.
-
Meta-analysis of hemodynamic optimization: relationship to methodological quality.Crit Care. 2005;9(6):R771-9. doi: 10.1186/cc3902. Epub 2005 Nov 15. Crit Care. 2005. PMID: 16356226 Free PMC article.
-
Haemodynamic goal-directed therapy in cardiac and vascular surgery. A systematic review and meta-analysis.Interact Cardiovasc Thorac Surg. 2012 Nov;15(5):878-87. doi: 10.1093/icvts/ivs323. Epub 2012 Jul 24. Interact Cardiovasc Thorac Surg. 2012. PMID: 22833509 Free PMC article.
-
Hemodynamic goal-directed therapy and postoperative kidney injury: an updated meta-analysis with trial sequential analysis.Crit Care. 2019 Jun 26;23(1):232. doi: 10.1186/s13054-019-2516-4. Crit Care. 2019. PMID: 31242941 Free PMC article.
-
Mixed venous O2 saturation and fluid responsiveness after cardiac or major vascular surgery.J Cardiothorac Surg. 2013 Sep 22;8:189. doi: 10.1186/1749-8090-8-189. J Cardiothorac Surg. 2013. PMID: 24053433 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials