Transthoracic admittance plethysmograph for measuring cardiac output
- PMID: 931862
- DOI: 10.1152/jappl.1976.40.3.451
Transthoracic admittance plethysmograph for measuring cardiac output
Abstract
A plethysmograph for measuring ventricular stroke volume (SV) from the transthoracic admittance variation was developed. A correlation study between the SV values determined by this method (SVy) and those measured by Kubicek's transthoracic impedance method (SVz) was carried out on 24 healthy subjects; the correlation coefficient was r = 0.99 and the regression line of SVY on SVz was y = 1.03x - 0.47. Based on the results obtained through the study, it was concluded that the admittance method was more advantageous than the impedance method for measuring SV.
Similar articles
-
[Transthoracic electrical impedance plethysmography and thermodilution: comparative evaluation of two methods for cardiac output measurement in man].Ann Fr Anesth Reanim. 1982;1(1):67-75. doi: 10.1016/s0750-7658(82)80078-6. Ann Fr Anesth Reanim. 1982. PMID: 7137667 French.
-
Stroke volume measurement by impedance cardiography using a formula based on the delta z waveform.Clin Phys Physiol Meas. 1982 May;3(2):131-9. doi: 10.1088/0143-0815/3/2/003. Clin Phys Physiol Meas. 1982. PMID: 6126290
-
[Measurement of cardiac output by electrical impedance plethysmography during respiration and in apnea].Ann Anesthesiol Fr. 1980;21(5):567-71. Ann Anesthesiol Fr. 1980. PMID: 6109507 French.
-
[Possibilities and prospects for the technic of tetrapolar transthoracic impedance rheoplethysmography for noninvasive study of hemo- and cardiodynamics].Fiziol Zh (1978). 1979 Jul-Aug;25(4):465-71. Fiziol Zh (1978). 1979. PMID: 381030 Review. Russian. No abstract available.
-
[Impedance cardiography and cardiac output].Rinsho Byori. 1983 Oct;Spec No 57:30-42. Rinsho Byori. 1983. PMID: 6371320 Review. Japanese. No abstract available.
Cited by
-
A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method.Med Biol Eng Comput. 2000 Jan;38(1):17-25. doi: 10.1007/BF02344683. Med Biol Eng Comput. 2000. PMID: 10829385 Clinical Trial.
-
Noninvasive measurement of elastic properties in human finger arteries: clinical data comparing blood pressure and funduscopic examination.Heart Vessels. 1988;4(4):221-8. doi: 10.1007/BF02058590. Heart Vessels. 1988. PMID: 3254902
-
Noninvasive measurement of arterial elasticity in various human limbs.Med Biol Eng Comput. 1988 Nov;26(6):641-6. doi: 10.1007/BF02447504. Med Biol Eng Comput. 1988. PMID: 3256758 No abstract available.
-
Electric impedance cuff for the indirect measurement of blood pressure and volume elastic modulus in human limb and finger arteries.Med Biol Eng Comput. 1989 Sep;27(5):477-83. doi: 10.1007/BF02441465. Med Biol Eng Comput. 1989. PMID: 2622228
-
Voltage clamp method for the use of electrical admittance plethysmography in human body segments.Med Biol Eng Comput. 1995 Sep;33(5):740-3. doi: 10.1007/BF02510798. Med Biol Eng Comput. 1995. PMID: 8523922 No abstract available.