Aspects of performance assessment of whole body imaging systems
- PMID: 9323269
- DOI: 10.1007/s002590050152
Aspects of performance assessment of whole body imaging systems
Abstract
Regular quality control is one of the cornerstones of nuclear medicine and a prerequisite for adequate diagnostic imaging. Many papers have been published on quality control of planar and tomographic imaging systems. Up to now, however, only minor attention has been given to the assessment of the performance of whole body imaging systems. In this paper we present a comprehensive set of test procedures including acceptance testing and regular quality control. It is not our purpose to present a thorough analysis of the methods and results. The selection of the tests is discussed and the tests are described; some results are presented. In addition action thresholds are proposed. The quality control tests can be applied to systems with either a moving detector or a moving imaging table, and to both detectors with a large field of view and detectors with a small field of view. The tests presented in this paper do not require special phantoms or sources other than those used for quality control of stationary gamma cameras. They can be applied for acceptance testing and for performance testing in a regular quality assurance programme.
Similar articles
-
Assessment of an in-house phantom for the quality control of a clinical gamma camera.J Xray Sci Technol. 2020;28(3):461-470. doi: 10.3233/XST-190610. J Xray Sci Technol. 2020. PMID: 32145008
-
A Novel 141Ce-Based Flood Field Phantom: Assessment of Suitability for Daily Uniformity Testing in a Clinical Nuclear Medicine Department.J Nucl Med Technol. 2017 Sep;45(3):225-229. doi: 10.2967/jnmt.116.189340. Epub 2017 Apr 13. J Nucl Med Technol. 2017. PMID: 28408699
-
Collimator integrity.J Nucl Cardiol. 2006 Nov;13(6):889-91. doi: 10.1016/j.nuclcard.2006.10.004. J Nucl Cardiol. 2006. PMID: 17174822 Review. No abstract available.
-
[The effect of the measurement matrix on the quality of statical scintigraphic research].Med Radiol (Mosk). 1989 Dec;34(12):24-9. Med Radiol (Mosk). 1989. PMID: 2601588 Russian. No abstract available.
-
[Radionuclide radiation monitoring].Med Tekh. 1991 Jul-Aug;(4):38-40. Med Tekh. 1991. PMID: 1753866 Review. Russian.
Cited by
-
Routine quality control recommendations for nuclear medicine instrumentation.Eur J Nucl Med Mol Imaging. 2010 Mar;37(3):662-71. doi: 10.1007/s00259-009-1347-y. Eur J Nucl Med Mol Imaging. 2010. PMID: 20130859 No abstract available.
-
Acceptance testing for nuclear medicine instrumentation.Eur J Nucl Med Mol Imaging. 2010 Mar;37(3):672-81. doi: 10.1007/s00259-009-1348-x. Eur J Nucl Med Mol Imaging. 2010. PMID: 20135120 No abstract available.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical