Which method of flicker perimetry is most effective for detection of glaucomatous visual field loss?
- PMID: 9344350
Which method of flicker perimetry is most effective for detection of glaucomatous visual field loss?
Abstract
Purpose: The authors compared the efficacy of two different forms of flicker perimetry: temporal modulation perimetry (TMP), which measures contrast thresholds for a fixed temporal frequency, and critical flicker frequency (CFF), which measures the highest frequency for which flicker is detected at a fixed contrast.
Methods: The authors compared 16 patients with early to moderate glaucomatous visual field loss with 16 age-matched normal controls. Flicker stimuli consisted of 2 degrees diameter targets of 2 seconds in duration, presented in 44 locations throughout the central 30 degrees visual field. Flicker was presented within a cosine envelope to avoid temporal transients. For TMP, contrast sensitivity thresholds were measured for 8-Hz sinusoidal flicker; CFF thresholds were measured for a stimulus of 100% contrast.
Results: The results indicate that TMP and CFF produced similar test-retest reliability in normals. CFF had slightly better reliability in glaucoma patients. Receiver operating characteristic analysis revealed that TMP could provide better separation of normals and glaucoma patients than did CFF. Similar findings were obtained when the thresholds for both procedures were converted to Z scores.
Conclusions: Both methods of flicker perimetry testing provide acceptable test-retest reliability, and both can distinguish normal subjects from glaucoma patients. However, TMP is more effective in separating normal subjects from glaucoma patients than CFF, suggesting that TMP is the method of choice for detecting glaucomatous damage using flicker perimetry.
Similar articles
-
Screening for glaucomatous visual field loss with frequency-doubling perimetry.Invest Ophthalmol Vis Sci. 1997 Feb;38(2):413-25. Invest Ophthalmol Vis Sci. 1997. PMID: 9040475
-
Automated flicker perimetry in glaucoma using Octopus 311: a comparative study with the Humphrey Matrix.Acta Ophthalmol Scand. 2006 Apr;84(2):210-5. doi: 10.1111/j.1600-0420.2005.00588.x. Acta Ophthalmol Scand. 2006. PMID: 16637839
-
Variability in patients with glaucomatous visual field damage is reduced using size V stimuli.Invest Ophthalmol Vis Sci. 1997 Feb;38(2):426-35. Invest Ophthalmol Vis Sci. 1997. PMID: 9040476
-
[Informative value of psychophysical examinations aside from conventional white-white perimetry].Ophthalmologe. 1996 Aug;93(4):389-95. Ophthalmologe. 1996. PMID: 8963137 Review. German.
-
The diagnostic value of automated flicker threshold perimetry.Curr Opin Ophthalmol. 1999 Apr;10(2):135-9. doi: 10.1097/00055735-199904000-00010. Curr Opin Ophthalmol. 1999. PMID: 10537764 Review.
Cited by
-
A novel Bayesian adaptive method for mapping the visual field.J Vis. 2019 Dec 2;19(14):16. doi: 10.1167/19.14.16. J Vis. 2019. PMID: 31845976 Free PMC article.
-
The theory of critical flicker fusion frequency and its application in cataracts.Adv Ophthalmol Pract Res. 2022 Oct 22;3(1):29-32. doi: 10.1016/j.aopr.2022.10.002. eCollection 2023 Feb-Mar. Adv Ophthalmol Pract Res. 2022. PMID: 37846427 Free PMC article. Review.
-
Novel Machine-Learning Based Framework Using Electroretinography Data for the Detection of Early-Stage Glaucoma.Front Neurosci. 2022 May 4;16:869137. doi: 10.3389/fnins.2022.869137. eCollection 2022. Front Neurosci. 2022. PMID: 35600610 Free PMC article.
-
Comparison of frequency doubling and flicker defined form perimetry in early glaucoma.Graefes Arch Clin Exp Ophthalmol. 2016 May;254(5):937-46. doi: 10.1007/s00417-016-3286-1. Epub 2016 Feb 17. Graefes Arch Clin Exp Ophthalmol. 2016. PMID: 26883356
-
Perceptual learning of motion leads to faster flicker perception.PLoS One. 2006 Dec 20;1(1):e28. doi: 10.1371/journal.pone.0000028. PLoS One. 2006. PMID: 17183655 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical