Current keratoconus detection methods compared with a neural network approach
- PMID: 9344352
Current keratoconus detection methods compared with a neural network approach
Abstract
Purpose: Four videokeratographic methods for keratoconus detection were compared with a neural network approach.
Methods: A classification neural network for keratoconus screening was designed to detect the presence of keratoconus (KC) or keratoconus suspects (KCS); a separate cone severity network graded the severity of conelike topography patterns consistent with KC or KCS. Three hundred TMS-1 examinations (Tomey) were randomly divided into training and test sets. Ten topographic indexes were network inputs. Nine categories were used: normal, astigmatism, KC, KCS, contact lens-induced warpage, pellucid marginal degeneration, photorefractive keratectomy, radial keratotomy, and penetrating keratoplasty. KC was subdivided into KC1 (mild), KC2 (moderate), and KC3 (advanced). There were three outputs for the classification network (KC, KCS, and OTHER); target output values of 0 = OTHER, 0.25 = KCS, 0.5 = KC1, 0.75 = KC2, and 1.0 = KC3 were used for the severity network.
Results: The best-trained classification network had 100% accuracy, specificity, and sensitivity for the test set. The severity network had mean outputs (+/-standard deviation) of OTHER = 0.02+/-0.02, KCS = 0.21+/-0.05, KC1 = 0.52+/-0.17, KC2 = 0.74+/-0.12, and KC3 = 0.91+/-0.15. The severity network output for all categories was well correlated to the keratoconus prediction index (R = 0.892, P < 0.0001). The classification network had an overall accuracy and specificity significantly better (P < or = 0.005) than the Klyce/Maeda keratoconus index (KCI) test, the Rabinowitz test (K & I-S), and simulated keratometry (average Sim K). However, there were no significant differences in keratoconus sensitivity between the classification network, KCI, and K & I-S. The sensitivity and specificity of average Sim K were significantly worse than those of the other tests. The classification network had significantly better sensitivity (P < 0.001) and specificity (P = 0.025) for KCS detection than the K & I-S.
Conclusions: The neural networks completely distinguished KC from KCS and from topographies that resembled KC. The network approach equaled the sensitivity of currently used tests for keratoconus detection and outperformed them in terms of accuracy and specificity.
Similar articles
-
Automated keratoconus screening with corneal topography analysis.Invest Ophthalmol Vis Sci. 1994 May;35(6):2749-57. Invest Ophthalmol Vis Sci. 1994. PMID: 8188468
-
Neural network classification of corneal topography. Preliminary demonstration.Invest Ophthalmol Vis Sci. 1995 Jun;36(7):1327-35. Invest Ophthalmol Vis Sci. 1995. PMID: 7775110
-
Goodness-of-prediction of Zernike polynomial fitting to corneal surfaces.J Cataract Refract Surg. 2005 Dec;31(12):2350-5. doi: 10.1016/j.jcrs.2005.05.025. J Cataract Refract Surg. 2005. PMID: 16473230
-
[Videokeratoscopy].J Fr Ophtalmol. 1999 Mar;22(2):241-54. J Fr Ophtalmol. 1999. PMID: 10327358 Review. French. No abstract available.
-
Indices for the detection of keratoconus.Oftalmologia. 2010;54(2):19-29. Oftalmologia. 2010. PMID: 20827908 Review.
Cited by
-
Keratoconus severity identification using unsupervised machine learning.PLoS One. 2018 Nov 6;13(11):e0205998. doi: 10.1371/journal.pone.0205998. eCollection 2018. PLoS One. 2018. PMID: 30399144 Free PMC article.
-
Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography.Case Rep Ophthalmol. 2013 Oct 25;4(3):199-209. doi: 10.1159/000356123. eCollection 2013. Case Rep Ophthalmol. 2013. PMID: 24348403 Free PMC article.
-
Presence of Fleischer ring and prominent corneal nerves in keratoconus relatives and normal controls.Int J Ophthalmol. 2015 Oct 18;8(5):922-7. doi: 10.3980/j.issn.2222-3959.2015.05.12. eCollection 2015. Int J Ophthalmol. 2015. PMID: 26558202 Free PMC article.
-
CLMI: the cone location and magnitude index.Cornea. 2008 May;27(4):480-7. doi: 10.1097/ICO.0b013e31816485d3. Cornea. 2008. PMID: 18434854 Free PMC article.
-
Corneal elevation topography: best fit sphere, elevation distance, asphericity, toricity, and clinical implications.Cornea. 2011 May;30(5):508-15. doi: 10.1097/ICO.0b013e3181fb4fa7. Cornea. 2011. PMID: 21107250 Free PMC article.