A model for the lateral penumbra in water of a 200-MeV proton beam devoted to clinical applications
Abstract
An experimental approach for modeling the lateral penumbra of a proton beam has been investigated. Measurements were made with a silicon diode in a water tank. Several geometrical configurations (phantom position, collimator-to-surface distance, collimator diameter, bolus thickness, air gap, etc.) and beam characteristics (range, modulation, etc.) have been studied. The results show that the lateral penumbra is almost independent of the beam modulation and the diameter of the collimator. The use of scaled variables for depth and penumbra allows us to represent the increase in penumbra with depth for any configuration with a second order polynomial function, provided that the penumbra at the entrance of the medium and at the depth of the range are known.
Similar articles
-
Measurements of lateral penumbra for uniform scanning proton beams under various beam delivery conditions and comparison to the XiO treatment planning system.Med Phys. 2013 Sep;40(9):091708. doi: 10.1118/1.4818283. Med Phys. 2013. PMID: 24007141
-
Comparison between the lateral penumbra of a collimated double-scattered beam and uncollimated scanning beam in proton radiotherapy.Phys Med Biol. 2008 Mar 21;53(6):1729-50. doi: 10.1088/0031-9155/53/6/016. Epub 2008 Mar 7. Phys Med Biol. 2008. PMID: 18367800
-
Proton beam penumbra: effects of separation between patient and beam modifying devices.Med Phys. 1986 Sep-Oct;13(5):734-41. doi: 10.1118/1.595974. Med Phys. 1986. PMID: 3023803
-
Benchmarking analytical calculations of proton doses in heterogeneous matter.Med Phys. 2005 Dec;32(12):3511-23. doi: 10.1118/1.2064887. Med Phys. 2005. PMID: 16475750
-
[Proton therapy].Radioisotopes. 1989 Jan;38(1):28-39. doi: 10.3769/radioisotopes.38.28. Radioisotopes. 1989. PMID: 2539610 Review. Japanese. No abstract available.
Cited by
-
Dosimetric Characteristics of a Two-Dimensional Diode Array Detector Irradiated with Passively Scattered Proton Beams.Cancers (Basel). 2015 Jul 30;7(3):1425-35. doi: 10.3390/cancers7030844. Cancers (Basel). 2015. PMID: 26264024 Free PMC article.
-
Clinical characterization of a proton beam continuous uniform scanning system with dose layer stacking.Med Phys. 2008 Nov;35(11):4945-54. doi: 10.1118/1.2982248. Med Phys. 2008. PMID: 19070228 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous