Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Oct;134(4):680-4.
doi: 10.1016/s0002-8703(97)70051-6.

Arterial remodeling after balloon angioplasty of the coronary artery: an intravascular ultrasound study. PICTURE Investigators. PostTreatment IntraCoronary Transluminal Ultrasound Result Evaluation

Affiliations

Arterial remodeling after balloon angioplasty of the coronary artery: an intravascular ultrasound study. PICTURE Investigators. PostTreatment IntraCoronary Transluminal Ultrasound Result Evaluation

G Pasterkamp et al. Am Heart J. 1997 Oct.

Abstract

Objective: Before balloon dilation, failure of compensatory enlargement and even arterial shrinkage are frequently observed at the lesion site in response to plaque accumulation. Balloon angioplasty may be regarded as artificial remodeling to enlarge the artery. The prevalence of the different types of arterial wall remodeling after applied stretch by balloon angioplasty is unknown.

Methods and results: In 181 patients an intravascular ultrasound study was performed after coronary balloon angioplasty (n = 200 lesions). The vessel area was measured at a proximal and distal reference site and at the lesion site. Subsequently, the relative vessel area [(Vessel area lesion site)/Vessel area reference site) x 100] was calculated. Lesions were classified in three groups on the basis of their relative vessel areas: > or =105%, <105% but >95%, and < or =95%. A relative vessel area > or =105%, indicating enlargement compared with the reference site, was observed in 84 (44%) lesions. A relative vessel area <105% but >95% was observed in 43 (22%) lesions. A relative vessel area < or =95%, indicating "shrinkage" compared with the reference site, was observed in 66 (34%) lesions.

Conclusions: After balloon angioplasty, the vessel area was found to be smaller compared with the reference site in 34% of the lesions. This small vessel area at the lesion site compared with a reference site may be a reflection of insufficient stretch by balloon angioplasty.

PubMed Disclaimer

MeSH terms

LinkOut - more resources