Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1997 Nov;169(5):1275-80.
doi: 10.2214/ajr.169.5.9353441.

Helical CT combined with contrast material administered only through the colon for imaging of suspected appendicitis

Affiliations
Clinical Trial

Helical CT combined with contrast material administered only through the colon for imaging of suspected appendicitis

P M Rao et al. AJR Am J Roentgenol. 1997 Nov.

Abstract

Objective: Helical CT combined with contrast material administered by mouth and through the colon has been shown to be accurate for appendiceal imaging. This investigation was performed to determine if helical CT combined with contrast material administered only through the colon has comparable accuracy.

Subjects and methods: One hundred patients prospectively underwent appendiceal CT imaging with thin-collimation, helical scanning limited to the lower abdomen and upper pelvis after contrast material was administered only through the colon. CT results were correlated with surgical and pathologic findings at appendectomy (56 patients), other surgery (three patients), or clinical follow-up at least 2 months after the CT scan (41 patients).

Results: Fifty-three CT scans were interpreted as positive for appendicitis, including 52 true-positives (with surgical-pathologic correlation) and on false-positive (with clinical follow-up). Forty-seven CT scans were interpreted as negative for appendicitis, including 40 true-negatives with clinical follow-up, three true-negatives with appendectomy and pathologic correlation, three true-negatives with other surgery and pathologic correlation, and one false-negative with appendectomy and pathologic correlation. CT had a 98% sensitivity, 98% specificity, 98% positive predictive value, 98% negative predictive value, and 98% accuracy for diagnosing or excluding appendicitis. In 47 normal appendix cases at CT, the appendix was seen in 44 cases (94%), and an alternative diagnosis was identified in 29 cases (62%).

Conclusion: For diagnosing appendicitis, helical CT combined with contrast material administered only through the colon proved to be as accurate (98%) as helical CT combined with contrast material administered by mouth and through the colon. Helical CT with contrast material administered only through the colon also could be performed immediately and without any of the potential patient risks or discomforts of contrast material administered i.v. or by mouth.

PubMed Disclaimer

Comment in

Publication types