Parametric representation and screening of knee joint vibroarthrographic signals
- PMID: 9353986
- DOI: 10.1109/10.641334
Parametric representation and screening of knee joint vibroarthrographic signals
Abstract
We have been investigating analysis of knee joint vibration or vibroarthrographic (VAG) signals as a potential tool for noninvasive diagnosis and monitoring of cartilage pathology. In this paper, we present a comprehensive comparative study of different parametric representations of VAG signals. Dominant poles and cepstral coefficients were derived from autoregressive models of adaptively segmented VAG signals. Signal features and a few clinical features were used as feature vectors in pattern classification experiments based on logistic regression analysis and the leave-one-out method. The results using 51 normal and 39 abnormal signals indicated the superior performance of cepstral coefficients in VAG signal classification with an accuracy rate of 75.6%. With 51 normal and 20 abnormal signals limited to chondromalacia patella, cepstral coefficients again gave the highest accuracy rate of 85.9%.
Similar articles
-
Adaptive time-frequency analysis of knee joint vibroarthrographic signals for noninvasive screening of articular cartilage pathology.IEEE Trans Biomed Eng. 2000 Jun;47(6):773-83. doi: 10.1109/10.844228. IEEE Trans Biomed Eng. 2000. PMID: 10833852
-
Screening of vibroarthrographic signals via adaptive segmentation and linear prediation modeling.IEEE Trans Biomed Eng. 1996 Jan;43(1):15-23. doi: 10.1109/10.477697. IEEE Trans Biomed Eng. 1996. PMID: 8567002
-
Modified local discriminant bases algorithm and its application in analysis of human knee joint vibration signals.IEEE Trans Biomed Eng. 2006 Mar;53(3):517-23. doi: 10.1109/TBME.2005.869787. IEEE Trans Biomed Eng. 2006. PMID: 16532778
-
Vibroarthrography--a possible functional non-invasive method for early detection damaged cartilage joint.Rom J Intern Med. 2006;44(4):471-6. Rom J Intern Med. 2006. PMID: 18386624 Review.
-
[The knee joint--imaging].Wien Med Wochenschr. 1997;147(23-24):542-7. Wien Med Wochenschr. 1997. PMID: 9542004 Review. German.
Cited by
-
Automatic de-noising of knee-joint vibration signals using adaptive time-frequency representations.Med Biol Eng Comput. 2000 Jan;38(1):2-8. doi: 10.1007/BF02344681. Med Biol Eng Comput. 2000. PMID: 10829383
-
Acoustical Emission Analysis by Unsupervised Graph Mining: A Novel Biomarker of Knee Health Status.IEEE Trans Biomed Eng. 2018 Jun;65(6):1291-1300. doi: 10.1109/TBME.2017.2743562. Epub 2017 Aug 29. IEEE Trans Biomed Eng. 2018. PMID: 28858782 Free PMC article.
-
A Feasibility Study on Tribological Origins of Knee Acoustic Emissions.IEEE Trans Biomed Eng. 2022 May;69(5):1685-1695. doi: 10.1109/TBME.2021.3127030. Epub 2022 Apr 21. IEEE Trans Biomed Eng. 2022. PMID: 34757899 Free PMC article.
-
Synthesis of vibroarthrographic signals in knee osteoarthritis diagnosis training.BMC Res Notes. 2016 Jul 19;9:352. doi: 10.1186/s13104-016-2156-6. BMC Res Notes. 2016. PMID: 27435313 Free PMC article.
-
Screening of knee-joint vibroarthrographic signals using statistical parameters and radial basis functions.Med Biol Eng Comput. 2008 Mar;46(3):223-32. doi: 10.1007/s11517-007-0278-7. Epub 2007 Oct 25. Med Biol Eng Comput. 2008. PMID: 17960443
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical