Forces, moments, and acceleration acting on a restrained dummy during simulation of three possible accidents involving a wheelchair negotiating a curb: comparison between lap belt and four-point belt
- PMID: 9354490
- DOI: 10.1097/00002060-199709000-00004
Forces, moments, and acceleration acting on a restrained dummy during simulation of three possible accidents involving a wheelchair negotiating a curb: comparison between lap belt and four-point belt
Abstract
The objective of this study was to determine the effect of two types of restraining belts (lap belt and a four-point belt) on an instrumented dummy during three situations: wheelchair hitting straight into curb (SIC); wheelchair falling straight off a curb (SOC); wheelchair falling diagonally off a curb (DOC). A fully instrumented (50th percentile Hybrid III) dummy was seated in a standard wheelchair and restrained with one of the belts. The wheelchair rolled down a ramp reaching a platform at 2.4 miles per hour (comfortable walking speed). Three types of experiments were performed: SIC, SOC, DOC. Each experiment was repeated at least three times. Forces, moments, and acceleration were monitored and recorded via 48 sensors placed at the head, spine, and limbs. All experiments were videotaped and photographed. The data were averaged and compared with standards that have been previously established in car crash testing and with data recently obtained in a similar study using a nonrestrained dummy. Our results showed that in the SIC experiments, low magnitude forces, moments, and acceleration of no clinical significance were recorded with both types of belts. The wheelchair remained upright and the dummy safely seated. In the SOC experiments, the two belts prevented the dummy's ejection from the chair and, thus, have been effective in lowering the forces, moments, and acceleration and preventing significant injuries to the head and neck regions. In the DOC experiments, the lap belt proved to be somewhat more effective than the four-point belt in lowering the extension forces at the upper neck and the moments at the lower neck below injury levels. It also kept the head injury criteria well below injury level. We postulate that the four-point belt was less effective because of its more extensive body fixation, which leads to concentration of moments and forces at the head and lower neck regions. The results of this study show that restraining systems can enhance the safety of wheelchair occupants in certain incidents. It has been demonstrated that the lap belt is as effective as the four-point belt system in SIC and SOC incidents. In DOC falls, neither belt could prevent falls and trauma to the head and neck region. The lap belt, however, was somewhat superior. We recommend that wheelchairs be equipped with a lap belt and patients be encouraged to buckle-up while using the wheelchair outdoors.
Similar articles
-
The dynamics of electric powered wheelchair sideways tips and falls: experimental and computational analysis of impact forces and injury.J Neuroeng Rehabil. 2016 Mar 2;13:20. doi: 10.1186/s12984-016-0128-7. J Neuroeng Rehabil. 2016. PMID: 26935331 Free PMC article.
-
Forces, moments, and accelerations acting on an unrestrained dummy during simulations of three wheelchair accidents.Am J Phys Med Rehabil. 1997 Jul-Aug;76(4):304-10. doi: 10.1097/00002060-199707000-00009. Am J Phys Med Rehabil. 1997. PMID: 9267190
-
Influence of belt pretensioning on dummy responses in 40 km/h rear-impact sled tests.Traffic Inj Prev. 2012;13(1):65-71. doi: 10.1080/15389588.2011.629558. Traffic Inj Prev. 2012. PMID: 22239146
-
Review of the use of physical restraints and lap belts with wheelchair users.Assist Technol. 2007 Summer;19(2):94-107. doi: 10.1080/10400435.2007.10131868. Assist Technol. 2007. PMID: 17727076 Review.
-
Seat belt pre-pretensioner effect on child-sized dummies during run-off-road events.Traffic Inj Prev. 2017 May 29;18(sup1):S96-S102. doi: 10.1080/15389588.2017.1312000. Epub 2017 Apr 12. Traffic Inj Prev. 2017. PMID: 28402687 Review.
Cited by
-
Effectiveness of Wearable Protection Equipment for Seated Pedestrians.Ann Biomed Eng. 2023 Sep;51(9):2086-2096. doi: 10.1007/s10439-023-03249-3. Epub 2023 May 30. Ann Biomed Eng. 2023. PMID: 37249726
-
Factors associated with injury severity among users of powered mobility devices.Clin Exp Emerg Med. 2021 Jun;8(2):103-110. doi: 10.15441/ceem.20.078. Epub 2021 Jun 30. Clin Exp Emerg Med. 2021. PMID: 34237815 Free PMC article.
-
Factors that influence the risk of falling after spinal cord injury: a qualitative photo-elicitation study with individuals that use a wheelchair as their primary means of mobility.BMJ Open. 2020 Feb 25;10(2):e034279. doi: 10.1136/bmjopen-2019-034279. BMJ Open. 2020. PMID: 32102820 Free PMC article.
-
The dynamics of electric powered wheelchair sideways tips and falls: experimental and computational analysis of impact forces and injury.J Neuroeng Rehabil. 2016 Mar 2;13:20. doi: 10.1186/s12984-016-0128-7. J Neuroeng Rehabil. 2016. PMID: 26935331 Free PMC article.
-
Automatic Detection and Classification of Unsafe Events During Power Wheelchair Use.IEEE J Transl Eng Health Med. 2014 Oct 30;2:2100509. doi: 10.1109/JTEHM.2014.2365773. eCollection 2014. IEEE J Transl Eng Health Med. 2014. PMID: 27170879 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials