Evaluation of peritoneal membrane integrity
- PMID: 9364314
Evaluation of peritoneal membrane integrity
Abstract
Peritoneal transport studies provide information on the vascular site the peritoneal membrane. The mass transfer area coefficient of creatinine mainly reflects the vascular peritoneal surface area, while the restriction coefficient to macromolecules reveals the intrinsic permeability of the peritoneal membrane. The Na+ dialysate/plasma ratio after a one hour 3.86% glucose dwell can be used as a rough indication of aquaporin-mediated water transport. Dialysate concentrations of cancer antigen 125 reflect the mesothelial cell mass. Ultrafiltration failure is the most frequent transport abnormality in long-term peritoneal dialysis and peritoneal sclerosis. Its association with high mass transfer area coefficients of creatinine suggests an increase in the vascular surface area due to neoangiogenesis, but the aquaporin-mediated water transport may also be disturbed. The decrease in dialysate CA 125 is compatible with a loss of mesothelial cell mass in long-term peritoneal dialysis. A proposal for a peritoneal membrane test is put forward. The main differences with the peritoneal equilibration test are: the use of 3.86% glucose, the determination of the Na+ dialysate/plasma ratio after one hour and of the dialysate CA 125 concentration after four hours.
Similar articles
-
The relationship between peritoneal transport characteristics and messenger RNA expression of aquaporin in the peritoneal dialysis effluent of CAPD patients.J Nephrol. 2005 Mar-Apr;18(2):197-203. J Nephrol. 2005. PMID: 15931648
-
Dialysate CA125 in stable CAPD patients: no relation with transport parameters.Clin Nephrol. 1995 Oct;44(4):248-54. Clin Nephrol. 1995. PMID: 8575125
-
Amphotericin B, mercury chloride and peritoneal transport in rabbits.Clin Nephrol. 2001 Jul;56(1):60-8. Clin Nephrol. 2001. PMID: 11499660
-
Pharmacological manipulation of peritoneal transport in CAPD.Clin Nephrol. 1988;30 Suppl 1:S29-33. Clin Nephrol. 1988. PMID: 3052958 Review.
-
[How to use the peritoneum as a dialysis membrane. Methods of surveillance, criteria of efficacy and longevity as a dialysis membrane, consequences with respect to techniques of peritoneal dialysis].Nephrologie. 1995;16(1):19-31. Nephrologie. 1995. PMID: 7700417 Review. French.
Cited by
-
Baseline Peritoneal Membrane Transport Characteristics Are Associated with Peritonitis Risk in Incident Peritoneal Dialysis Patients.Membranes (Basel). 2022 Feb 28;12(3):276. doi: 10.3390/membranes12030276. Membranes (Basel). 2022. PMID: 35323751 Free PMC article.
-
Measuring transport of water across the peritoneal membrane.Kidney Int. 2003 Nov;64(5):1911-5. doi: 10.1046/j.1523-1755.2003.00253.x. Kidney Int. 2003. PMID: 14531827 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Research Materials