Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Nov;28(11):2201-7.
doi: 10.1161/01.str.28.11.2201.

Reproducibility of ultrasound assessment of carotid plaque occurrence, thickness, and morphology. The Tromsø Study

Affiliations

Reproducibility of ultrasound assessment of carotid plaque occurrence, thickness, and morphology. The Tromsø Study

O Joakimsen et al. Stroke. 1997 Nov.

Abstract

Background and purpose: Ultrasonography is increasingly used in vascular research, but there is limited information about the reproducibility of the ultrasound method for screening purposes. In this study the reproducibility of ultrasound assessment of carotid plaque occurrence, thickness, and morphology was examined within the setting of a population health survey.

Methods: In 1994/1995, 6720 participants in the Tromsø Study, Norway, underwent B-mode ultrasound scanning of the right carotid artery. The between- and within-sonographer reproducibility of ultrasound assessment of plaque occurrence and thickness was estimated by repeated scanning of a random sample of 107 participants. The between- and within-sonographer reproducibility of plaque morphology classification (echogenicity, four categories and heterogeneity, two categories) was determined by repeated reading of videotaped images of 119 randomly selected arteries with plaques.

Results: Between- and within-sonographer agreement on plaque occurrence was substantial with kappa values (95% CI) of 0.72 (0.60 to 0.84) and 0.76 (0.63 to 0.89), respectively. Reproducibility of plaque thickness measurements was moderate, with mean absolute differences ranging between 0.25 and 0.55 mm (coefficients of variation between 13.8% and 22.4%). Agreement on plaque morphology classification was high, with kappa values ranging between 0.54 and 0.73.

Conclusions: Population screening using B-mode ultrasound provides a valuable means for the detection and morphological evaluation of carotid plaques, whereas measurements of plaque thickness are subject to considerable measurement error.