Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1997 Oct;177(4):723-30.
doi: 10.1016/s0002-9378(97)70259-x.

Cervical ultrasonography compared with manual examination as a predictor of preterm delivery

Affiliations
Comparative Study

Cervical ultrasonography compared with manual examination as a predictor of preterm delivery

V Berghella et al. Am J Obstet Gynecol. 1997 Oct.

Abstract

Objective: Our purpose was to compare the accuracy of ultrasonographic and manual cervical examinations for the prediction of preterm delivery.

Study design: One hundred two singleton pregnancies at high risk for preterm delivery were followed up prospectively from 14 to 30 weeks with both serial cervical ultrasonography measurements and manual examinations of the length of the cervix. The primary outcome studied was preterm (< 35 weeks) delivery.

Results: Excluding six induced preterm deliveries, 96 pregnancies were analyzed. The mean cervical length measured by ultrasonography was 20.6 mm in pregnancies delivered preterm (n = 17) and 31.3 mm in pregnancies delivered at term (n = 79) (p = 0.003); the mean cervical lengths measured by manual examination were 16.1 mm and 18.6 mm in the same preterm and term pregnancies, respectively (not significant). The sixteenth- and twentieth-week ultrasonographic cervical lengths predicted preterm delivery most accurately (p < 0.0005). The 25th percentiles of ultrasonographic (25 mm) and manual (16 mm) cervical lengths showed relative risks for preterm delivery of 4.8 (95% confidence interval 2.1 to 11.1, p = 0.0004) and 2.0 (95% confidence interval 0.5 to 4.7, p = 0.1), respectively; sensitivity, specificity, and positive and negative predictive values were 59%, 85%, 45%, 91%, and 41%, 77%, 28%, and 86%, respectively.

Conclusion: Cervical length measured by ultrasonography is a better predictor of preterm delivery than is cervical length measured by manual examination. Cervical ultrasonography in patients at high risk for preterm birth seems to be most predictive of preterm delivery when it is performed between 14 and 22 weeks' gestation.

PubMed Disclaimer

Publication types