Arterial to end-tidal carbon dioxide gradient and physiological dead space monitoring during general anaesthesia: effects of patients' position
- PMID: 9374078
Arterial to end-tidal carbon dioxide gradient and physiological dead space monitoring during general anaesthesia: effects of patients' position
Abstract
Methods: One hundred and five ASA I-II patients, scheduled for elective surgical procedures were studied in order to evaluate the effect of different surgical postures on physiological pulmonary dead space (VDphys/ VT) and arterial to end-tidal carbon dioxide gradient [P(a-Et)CO2]. Patients were divided into four groups according to their position on the operating table: supine position (acting as control group, n = 33), 20 degree Trendelenburg position (n = 24), lateral position (n = 24) and prone position with convex saddle frame (n = 24). Physiologic dead space was measured using Enghoff modification of Bohr equation. Arterial CO2 partial pressure was measured by blood gas analysis and end tidal CO2 was measured by means of an infrared CO2 analyser. All measurements were performed 20 minutes after general anaesthesia induction, with patients mechanically ventilated by a constant inspiratory flow (TV = 8 ml kg-1, RR = 10-14, EIP = 10%) in order to reach a steady state end tidal CO2 ranging between 32 and 36 mmHg; afterwards surgery started.
Results: Arterial blood pressure showed a mean decrease of about 5-10% compared to baseline values, but no significant differences in arterial pressure decrease were found between the four groups. A significant VDphys/VT increase in postures other than supine was observed, unless it was statistically significant in lateral and prone position only; while P(a-Et)CO2 was higher in all postures compared to supine. Changes of intrapulmonary gas and blood distribution due to patients' posture are probably responsible for the observed physiologic dead space and CO2 gradient differences.
Conclusions: In conclusion, the clinical practice of predicting PaCO2 from EtCO2 must be tempered by recognition of the potential magnitude of P(a-Et)CO2 gradient, which is higher than normal during general anaesthesia and further increased when positioning the patient other than supine.
Similar articles
-
The effect of increased apparatus dead space and tidal volumes on carbon dioxide elimination and oxygen saturations in a low-flow anesthesia system.J Clin Anesth. 2008 May;20(3):170-4. doi: 10.1016/j.jclinane.2007.09.013. J Clin Anesth. 2008. PMID: 18502358 Clinical Trial.
-
[Laparoscopic cholecystectomy--effect of position changes and CO2 pneumoperitoneum on hemodynamic, respiratory and endocrinologic parameters].Zentralbl Chir. 1997;122(5):395-404. Zentralbl Chir. 1997. PMID: 9334103 German.
-
Predicting dead space ventilation in critically ill patients using clinically available data.Crit Care Med. 2010 Jan;38(1):288-91. doi: 10.1097/CCM.0b013e3181b42e13. Crit Care Med. 2010. PMID: 19789453
-
[Respiratory mechanics and gas exchange in anesthesia for laparoscopic cholecystectomy].Minerva Anestesiol. 1993 Oct;59(10):487-92. Minerva Anestesiol. 1993. PMID: 8302445 Review. Italian.
-
[Anesthesia relevant features of laparoscopy--the value of capnometry].Anaesthesiol Reanim. 1994;19(1):4-10. Anaesthesiol Reanim. 1994. PMID: 8141962 Review. German.
Cited by
-
Ventilation patterns in patients with severe traumatic brain injury following paramedic rapid sequence intubation.Neurocrit Care. 2005;2(2):165-71. doi: 10.1385/NCC:2:2:165. Neurocrit Care. 2005. PMID: 16159059
-
Difference between arterial and end-tidal carbon dioxide and adverse events after non-cardiac surgery: a historical cohort study.Can J Anaesth. 2022 Jan;69(1):106-118. doi: 10.1007/s12630-021-02118-8. Epub 2021 Oct 6. Can J Anaesth. 2022. PMID: 34617239 Free PMC article.
-
End-Tidal Carbon Dioxide Pressure Measurement after Prolonged Inspiratory Time Gives a Good Estimation of the Arterial Carbon Dioxide Pressure in Mechanically Ventilated Patients.Diagnostics (Basel). 2021 Nov 27;11(12):2219. doi: 10.3390/diagnostics11122219. Diagnostics (Basel). 2021. PMID: 34943456 Free PMC article.
-
A Patient-Ready Wearable Transcutaneous CO2 Sensor.Biosensors (Basel). 2022 May 13;12(5):333. doi: 10.3390/bios12050333. Biosensors (Basel). 2022. PMID: 35624634 Free PMC article.
-
Relationship Between Respiratory Dynamics and Body Mass Index in Patients Undergoing General Anesthesia with Laryngeal Mask Airway (LMA) and Comparison Between Lithotomy and Supine Positions.Med Sci Monit. 2016 Aug 1;22:2706-13. doi: 10.12659/msm.897086. Med Sci Monit. 2016. PMID: 27476762 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Medical