[Air microbiology monitoring in plenum-ventilated operating rooms. Proposed standards]
- PMID: 9376382
[Air microbiology monitoring in plenum-ventilated operating rooms. Proposed standards]
Abstract
Background: Microbiological standard for air in plenum ventilated operating theatres are not defined. The aim of this study was to analyze the microbiological contamination of air in HUSC theatres and to establish standards of reference.
Methods: 408 air samples (80 l/sample) were taken from air intake and center of the theatres in three surgical areas, throughout five consecutive years (1991-1995). RCS air sampler was used. Media of microbiological counts were compared using the ANOVA and the Kruskall-Wallis tests. Microbiological standards were established based on upper limit of confidence interval of counts, when the degree of contamination was similar in two consecutive years.
Results: A falling trend of microbiological counts was observed, with statistical significance between counts found in 1992 and those found in 1994 and 1995 (p < 0.01). There was no difference between results of the three surgical areas, but there was a significant difference between counts from air intake and center of theatres, regardless the year or the surgical area (p < 0.01). During this time a significant decrease in the percentage of samples with presence of fungi (p = 0.001) was produced. The results of years 1994 and 1995 were taken for establish the microbiological standards.
Conclusions: This control program allowed to evaluate and improve the hygienic conditions in the operating theatres and to establish a microbiological standards of reference for plenum ventilated theatres.
Similar articles
-
Monitoring air sampling in operating theatres: can particle counting replace microbiological sampling?J Hosp Infect. 2005 Sep;61(1):27-9. doi: 10.1016/j.jhin.2005.03.002. J Hosp Infect. 2005. PMID: 16009457
-
[Model for microbiological surveillance of operating rooms: analysis of the efficacy of total mesophilic load and air particle counts].Ig Sanita Pubbl. 2010 Mar-Apr;66(2):193-213. Ig Sanita Pubbl. 2010. PMID: 20552001 Italian.
-
Bacterial air contamination of operating theatres and surgical wards of a university teaching hospital.Afr J Med Med Sci. 1993 Jun;22(2):19-23. Afr J Med Med Sci. 1993. PMID: 7839891
-
[Does ultraclean air in the operating room provide greater safety?].Ned Tijdschr Geneeskd. 2010;154:A1598. Ned Tijdschr Geneeskd. 2010. PMID: 20356423 Review. Dutch.
-
Operating theatre ventilation standards and the risk of postoperative infection.J Hosp Infect. 2002 Feb;50(2):85-90. doi: 10.1053/jhin.2001.1126. J Hosp Infect. 2002. PMID: 11846534 Review.
Cited by
-
Developing a faster way to identify biocontamination in the air of controlled environment rooms with HEPA filters: airborne particle counting.Sci Rep. 2020 Feb 13;10(1):2575. doi: 10.1038/s41598-020-59367-8. Sci Rep. 2020. PMID: 32054928 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical