Argon pneumoperitoneum is more dangerous than CO2 pneumoperitoneum during venous gas embolism
- PMID: 9390610
- DOI: 10.1097/00000539-199712000-00034
Argon pneumoperitoneum is more dangerous than CO2 pneumoperitoneum during venous gas embolism
Abstract
We investigated the possibility of using argon, an inert gas, as a replacement for carbon dioxide (CO2). The tolerance of argon pneumoperitoneum was compared with that of CO2 pneumoperitoneum. Twenty pigs were anesthetized with enflurane 1.5%. Argon (n = 11) or CO2 (n = 9) pneumoperitoneum was created at 15 mm Hg over 20 min, and serial intravenous injections of each gas (ranging from 0.1 to 20 mL/kg) were made. Cardiorespiratory variables were measured. Transesophageal Doppler and capnographic monitoring were assessed in the detection of embolism. During argon pneumoperitoneum, there was no significant change from baseline in arterial pressure and pulmonary excretion of CO2, mean systemic arterial pressure (MAP), mean pulmonary artery pressure (PAP), or systemic and pulmonary vascular resistances, whereas CO2 pneumoperitoneum significantly increased these values (P < 0.05). During the embolic trial and from gas volumes of 2 and 0.2 mL/kg, the decrease in MAP and the increase in PAP were significantly higher with argon than with CO2 (P < 0.05). In contrast to CO2, argon pneumoperitoneum was not associated with significant changes in cardiorespiratory functions. However, argon embolism seems to be more deleterious than CO2 embolism. The possibility of using argon pneumoperitoneum during laparoscopy remains uncertain.
Implications: Laparoscopic surgery requires insufflation of gas into the peritoneal cavity. We compared the hemodynamic effects of argon, an inert gas, and carbon dioxide in a pig model of laparoscopic surgery. We conclude that argon carries a high risk factor in the case of an accidental gas embolism.
Similar articles
-
Hemodynamic effects of argon pneumoperitoneum.Surg Endosc. 1994 Apr;8(4):315-20; discussion 320-1. doi: 10.1007/BF00590961. Surg Endosc. 1994. PMID: 8209302
-
Cardiopulmonary responses to intravenous infusion of soluble and relatively insoluble gases.Surg Endosc. 1997 Apr;11(4):341-6. doi: 10.1007/s004649900359. Surg Endosc. 1997. PMID: 9094273
-
[Effects of argon gas embolism during pneumoperitoneum].Chirurg. 1999 Feb;70(2):184-8; discussion 189. doi: 10.1007/pl00002591. Chirurg. 1999. PMID: 10097864 German.
-
Laparoscopy: searching for the proper insufflation gas.Surg Endosc. 2000 Nov;14(11):1050-6. doi: 10.1007/s004640000216. Surg Endosc. 2000. PMID: 11116418 Review.
-
Fatal carbon dioxide embolism complicating attempted laparoscopic cholecystectomy--case report and literature review.J Forensic Sci. 1994 Nov;39(6):1468-80. J Forensic Sci. 1994. PMID: 7815026 Review.
Cited by
-
A complete review of preclinical and clinical uses of the noble gas argon: Evidence of safety and protection.Ann Card Anaesth. 2019 Apr-Jun;22(2):122-135. doi: 10.4103/aca.ACA_111_18. Ann Card Anaesth. 2019. PMID: 30971592 Free PMC article. Review.
-
Histologic characteristics of laparoscopic saline-enhanced electrosurgery of liver and splenic injuries.Surg Endosc. 2003 Nov;17(11):1739-43. doi: 10.1007/s00464-002-8638-8. Epub 2003 May 13. Surg Endosc. 2003. PMID: 12739124
-
Laparoscopic surgery and the parasympathetic nervous system.Surg Endosc. 2006 Aug;20(8):1225-32. doi: 10.1007/s00464-005-0280-9. Epub 2006 Jul 24. Surg Endosc. 2006. PMID: 16865627
-
CO2 abdominal insufflation pretreatment increases survival after a lipopolysaccharide-contaminated laparotomy.J Gastrointest Surg. 2006 Jan;10(1):32-8. doi: 10.1016/j.gassur.2005.07.031. J Gastrointest Surg. 2006. PMID: 16368488
-
The "Dark Side" of Pneumoperitoneum and Laparoscopy.Minim Invasive Surg. 2021 May 19;2021:5564745. doi: 10.1155/2021/5564745. eCollection 2021. Minim Invasive Surg. 2021. PMID: 34094598 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials