Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1997 Spring;3(1):21-9.
doi: 10.1089/acm.1997.3.21.

Double-blind study of pulsing magnetic field effects on multiple sclerosis

Affiliations
Clinical Trial

Double-blind study of pulsing magnetic field effects on multiple sclerosis

T L Richards et al. J Altern Complement Med. 1997 Spring.

Erratum in

  • J Altern Complement Med 1997 Summer;3(2):205

Abstract

We performed a double-blind study to measure the clinical and subclinical effects of an alternative medicine magnetic device on disease activity in multiple sclerosis (MS). The MS patients were exposed to a magnetic pulsing device (Enermed) where the frequency of the magnetic pulse was in the 4-13 Hz range (50-100 milliGauss). A total of 30 MS patients wore the device on preselected sites between 10 and 24 hours a day for 2 months. Half of the patients (15) randomly received an Enermed device that was magnetically inactive and the other half received an active device. Each MS patient received a set of tests to evaluate MS disease status before and after wearing the Enermed device. The tests included (1) a clinical rating (Kurtzke, EDSS), (2) patient-reported performance scales, and (3) quantitative electroencephalography (QEEG) during a language task. Although there was no significant change between pretreatment and posttreatment in the EDSS scale, there was a significant improvement in the performance scale (PS) combined rating for bladder control, cognitive function, fatigue level, mobility, spasticity, and vision (active group -3.83 +/- 1.08, p < 0.005; placebo group -0.17 +/- 1.07, change in PS scale). There was also a significant change between pretreatment and posttreatment in alpha EEG magnitude during the language task recorded at various electrode sites on the left side. In this double-blind, placebo-controlled study, we have demonstrated a statistically significant effect of the Enermed magnetic pulsing device on patient performance scales and on alpha EEG magnitude during a language task.

PubMed Disclaimer

Publication types

LinkOut - more resources