Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Dec;42(4):388-93.
doi: 10.1002/(sici)1097-0304(199712)42:4<388::aid-ccd7>3.0.co;2-7.

Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: initial human experience

Affiliations

Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: initial human experience

J Masura et al. Cathet Cardiovasc Diagn. 1997 Dec.

Abstract

Transcatheter closure of secundum atrial septal defect (ASD) using clamshell or buttoned devices is accompanied by a high incidence of residual shunt. Recently, a new self-centering device, the Amplatzer septal occluder (ASO), has been evaluated in an animal model with very good results. Therefore, our purpose is to report on our initial clinical experience with this device. Thirty patients underwent an attempt at catheter closure of their ASDs at a median age of 6.1 yr (range, 2.9-62.4 yr) and median weight of 22 kg (range, 13-69 kg) using the ASO. The median ASD diameter measured by transesophageal echocardiography (TEE) was 12.5 mm (range, 5-21 mm), and the median ASD balloon stretched diameter was 14 mm (range, 7-19 mm). All patients had right atrial and ventricular volume overload with a mean +/- SD Qp/Qs of 2.3 +/- 0.6. A 7F catheter was used for delivery of the device in all patients. The device was placed correctly in all patients. There was immediate and complete closure (C) in 17/30 patients, 10 patients had trivial residual shunt (TS), and 3 had moderate residual shunt (MS). The median fluoroscopy time was 15 min (range, 8-35 min), and the median total procedure time was 92.5 min (range, 40-135 min). There was no episode of device embolization or any other complication. Follow-up was performed using transthoracic echocardiography (TTE) 1 day, 1 mo, 3 mo, and yearly thereafter. At 1 day, there was C of the ASD in 24/30 patients, 3 had TS, 1 had small shunt (SS), and 2 had MS. At a median follow-up interval of 6 mo, there have been no episodes of endocarditis, thromboembolism, or wire fracture. We conclude that the use of the new ASO is safe and effective in complete closure of secundum ASDs up to a diameter of 21 mm in the majority of patients. Further clinical trials are underway.

PubMed Disclaimer

Comment in

  • Promises, promises..
    Block PC. Block PC. Cathet Cardiovasc Diagn. 1997 Dec;42(4):394. doi: 10.1002/(sici)1097-0304(199712)42:4<394::aid-ccd9>3.0.co;2-6. Cathet Cardiovasc Diagn. 1997. PMID: 9408618 No abstract available.
  • Letter to the editor: re Hijazi.
    Abhaichand RK, Joseph G. Abhaichand RK, et al. Cathet Cardiovasc Diagn. 1998 Aug;44(4):456. doi: 10.1002/(sici)1097-0304(199808)44:4<456::aid-ccd22>3.0.co;2-f. Cathet Cardiovasc Diagn. 1998. PMID: 9716218 No abstract available.

LinkOut - more resources