Voltage-sensitive dye recordings of electrophysiological activation in a Langendorff-perfused mouse heart
- PMID: 9413241
Voltage-sensitive dye recordings of electrophysiological activation in a Langendorff-perfused mouse heart
Abstract
The pattern of electrophysiological activation of adult mouse ventricles was measured with the use of voltage-sensitive dye methods. Di-4-ANEPPS was used to monitor membrane potential as small changes in fluorescence, which were detected by a state of the art, cooled, charged coupled device camera/image intensifier system. The extremely rapid conduction velocity, coupled with the small size of this preparation, necessitated taking these measurements at room temperature (22 to 23 degrees C). Initial experiments demonstrate that ventricular activation can be identified and its conduction pattern can be monitored reproducibly and with high resolution for extended time periods (10 to 20 mins) during spontaneous activity.
Similar articles
-
Effects of voltage sensitive dye di-4-ANEPPS on guinea pig and rabbit myocardium.Gen Physiol Biophys. 2008 Mar;27(1):45-54. Gen Physiol Biophys. 2008. PMID: 18436983
-
Measurements of electrophysiological effects of components of acute ischemia in Langendorff-perfused rat hearts using voltage-sensitive dye mapping.J Cardiovasc Electrophysiol. 2006 May;17 Suppl 1:S113-S123. doi: 10.1111/j.1540-8167.2006.00392.x. J Cardiovasc Electrophysiol. 2006. PMID: 16686665
-
Voltage-sensitive dye mapping of activation and conduction in adult mouse hearts.Ann Biomed Eng. 2000 Aug;28(8):958-67. doi: 10.1114/1.1308501. Ann Biomed Eng. 2000. PMID: 11144681
-
[Optical mapping of the membrane potential with voltage-sensitive dyes].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2006 Jun;23(3):665-8. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2006. PMID: 16856412 Review. Chinese.
-
Using voltage-sensitive dye recording to image the functional development of neuronal circuits in vertebrate embryos.Dev Neurobiol. 2008 May;68(6):804-16. doi: 10.1002/dneu.20629. Dev Neurobiol. 2008. PMID: 18383552 Review.
Cited by
-
What Is the Optimal Light Source for Optical Mapping Using Voltage- and Calcium-Sensitive Dyes?Physiol Res. 2020 Aug 31;69(4):599-607. doi: 10.33549/physiolres.934471. Epub 2020 Jun 25. Physiol Res. 2020. PMID: 32584139 Free PMC article.
-
Form follows function: developmental and physiological view on ventricular myocardial architecture.Eur J Cardiothorac Surg. 2005 Oct;28(4):526-8. doi: 10.1016/j.ejcts.2005.07.001. Eur J Cardiothorac Surg. 2005. PMID: 16126399 Free PMC article. Review.