Iliosacral screw fixation: early complications of the percutaneous technique
- PMID: 9415865
- DOI: 10.1097/00005131-199711000-00007
Iliosacral screw fixation: early complications of the percutaneous technique
Abstract
Objective: To report on the early complications related to the percutaneous placement of iliosacral screws for the operative treatment of displaced posterior pelvic ring disruptions.
Study design: Prospective, consecutive.
Setting: Level-one trauma center.
Patients: One hundred seventy-seven consecutive patients with unstable pelvic ring fractures. One hundred two male and seventy-five female patients ranging in age from eleven to seventy-eight years (mean, thirty-two years).
Interventions: Operative procedures were performed urgently according to the patient's clinical condition. Anterior pelvic reductions and fixations were performed by using internal and external fixation techniques. Accurate closed or open reductions of the posterior pelvic ring disruptions were accomplished by using a variety of surgical techniques dependent on the specific pattern of pelvic ring disruption. Closed manipulative reductions of the posterior pelvic ring were attempted for all patients. Open reductions were necessary in those patients with unacceptable closed manipulative reductions as assessed fluoroscopically at the time of operation (more than one centimeter in any field of fluoroscopic imaging).
Main outcome measures: Plain inlet and outlet radiographs were obtained postoperatively at six weeks, three months, and twelve months. A pelvic computed tomography scan was performed postoperatively to assess fracture or dislocation reduction and the implant safety. Annual follow-up pelvic radiographs were obtained. Residual pelvic deformities were quantified based on these imaging modalities.
Results: There were no posterior pelvic infections. Minimal blood loss was associated with this technique. Complications occurred due to inadequate imaging, surgeon error, and fixation failure. Fluoroscopic imaging was inadequate due to obesity or abdominal contrast in eighteen patients. Five screws were misplaced due to surgeon error. One misplaced screw produced a transient L5 neuropraxia. Fixation failures related to either crandiocerebral trauma, delayed union, noncomplicance, and a deep anterior pelvic polymicrobial infection secondary to a urethral tear occurred in seven patients. There were two sacral nonunions that required debridement, bone grafting, and repeat fixation prior to healing.
Conclusions: Iliosacral screw fixation of the posterior pelvis is difficult. The surgeon must understand the variability of sacral anatomy. Quality triplanar fluoroscopic imaging of the accurately reduced posterior pelvic ring should allow for safe iliosacral screw insertions. Anticipated noncompliant patients or those with craniocerebral trauma may need supplementary posterior pelvic fixation. Low rates of infection, blood loss, and nonunion can be expected.
Similar articles
-
Percutaneous stabilization of U-shaped sacral fractures using iliosacral screws: technique and early results.J Orthop Trauma. 2001 May;15(4):238-46. doi: 10.1097/00005131-200105000-00002. J Orthop Trauma. 2001. PMID: 11371788
-
Iliosacral screw fixation of the unstable pelvic ring injuries.Acta Chir Orthop Traumatol Cech. 2010 Jun;77(3):209-14. Acta Chir Orthop Traumatol Cech. 2010. PMID: 20619112
-
Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation.Injury. 2014 Jun;45(6):988-94. doi: 10.1016/j.injury.2014.01.015. Epub 2014 Jan 19. Injury. 2014. PMID: 24507831
-
Clinical Application of Navigation in the Surgical Treatment of a Pelvic Ring Injury and Acetabular Fracture.Adv Exp Med Biol. 2018;1093:289-305. doi: 10.1007/978-981-13-1396-7_22. Adv Exp Med Biol. 2018. PMID: 30306489 Review.
-
Percutaneous Sacroiliac Screw Fixation of the Posterior Pelvic Ring.Orthop Clin North Am. 2015 Oct;46(4):511-21. doi: 10.1016/j.ocl.2015.06.005. Epub 2015 Aug 6. Orthop Clin North Am. 2015. PMID: 26410639 Review.
Cited by
-
Treatment of pelvic fractures through a less invasive ilioinguinal approach combined with a minimally invasive posterior approach.BMC Musculoskelet Disord. 2015 Jul 25;16:167. doi: 10.1186/s12891-015-0635-x. BMC Musculoskelet Disord. 2015. PMID: 26205233 Free PMC article.
-
Intraoperative computerised tomography scan for percutaneous fixation of the pelvis: a retrospective case series.Int Orthop. 2024 Oct;48(10):2743-2748. doi: 10.1007/s00264-024-06265-7. Epub 2024 Aug 15. Int Orthop. 2024. PMID: 39143425 Free PMC article.
-
Use of calcaneal plates in the treatment of posterior pelvic ring injuries and displaced iliac blade fractures- A case series.J Clin Orthop Trauma. 2022 Dec 30;37:102091. doi: 10.1016/j.jcot.2022.102091. eCollection 2023 Feb. J Clin Orthop Trauma. 2022. PMID: 36632341 Free PMC article.
-
[Influence of sacral fracture on the long-term outcome of pelvic ring injuries].Unfallchirurg. 2005 Jan;108(1):35-36, 38-42. doi: 10.1007/s00113-004-0864-1. Unfallchirurg. 2005. PMID: 15674646 Clinical Trial. German.
-
[Sacrum fractures and lumbopelvic instabilities in pelvic ring injuries: classification and biomechanical aspects].Unfallchirurg. 2013 Nov;116(11):972-8. doi: 10.1007/s00113-012-2335-4. Unfallchirurg. 2013. PMID: 24233081 Review. German.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical