Comparative Study
. 1997 Oct;167(4):377-83.
doi: 10.1055/s-2007-1015547.

[MRI of the regions of the inner ear and cerebellopontine angle using a 3D T2-weighted turbo spin-echo sequence. Comparison with conventional 2D T2-weighted turbo spin-echo sequences and T1-weighted spin-echo sequences]

[Article in German]
Affiliations
Comparative Study

[MRI of the regions of the inner ear and cerebellopontine angle using a 3D T2-weighted turbo spin-echo sequence. Comparison with conventional 2D T2-weighted turbo spin-echo sequences and T1-weighted spin-echo sequences]

[Article in German]
C Czerny et al. Rofo. 1997 Oct.

Abstract

Purpose: To assess the value of a three-dimensional (3D) T2-weighted turbo spin-echo sequence (3D T2-TSE) in comparison to conventional two-dimensional (2D) T2-weighted TSE and unenhanced and enhanced T1-weighted spin-echo sequences (SE) in imaging anatomic structures and pathologic changes of the inner ear and cerebellopontine angle.

Patients and methods: The inner ear and cerebellopontine angle were investigated by MRI in three healthy volunteers and 18 patients performing a 2D T2-weighted turbo spin-echo sequence and a 3D T2-TSE in the axial plane. In the patient study, 2D T1-weighted SE sequences both before and after the i.v. injection of gadopentetate dimeglumine in both the axial and coronal plane were performed in addition.

Results: Only the 3D T2-TSE enabled an accurate imaging of the anatomic structures. In cases of pathology, the 3D T2-TSE provided additional information to the performed 2D sequences. The combination of the 3D T2-TSE with unenhanced and enhanced 2D T1-weighted SE enabled the most accurate diagnosis in cases of pathology.

Conclusions: Accurate depiction of anatomic structures of the inner ear and cerebellopontine angle could be obtained by 3D T2-TSE only. The most accurate diagnosis in cases of pathology was provided by the combination of the 3D T2-TSE with unenhanced and enhanced 2D T1-weighted spin-echo sequences.