[An experimental study of the treatment of aneurysms using an intravascular prosthesis]
- PMID: 9417478
[An experimental study of the treatment of aneurysms using an intravascular prosthesis]
Abstract
Intracranial aneurysms occur frequently with the risk of major damage. Neurosurgery or endovascular techniques can be used for treatment. Current techniques are not well adapted for aneurysms with a wide implantation (or neck). The aim of this experimental work was to study a technique for treating aneurysms which can be used for wide neck aneurysms. A metal stent is implanted facing the neck of the aneurysm to allow occlusion. In the first part of the study, the stent was inserted alone. Ten aneurysms were created surgically in five dogs. The stents were positioned facing seven of the ten aneurysms. The stent led to immediate occlusion of the aneurysm in six of the cases. One aneurysm remained patent despite the correct position of the stent. One dog developed secondary thrombosis of the carotid. Three dogs have been followed for sixty days after insertion of the stent. Two aneurysms thrombosed and one was patent. Since these results were less than satisfactory, a second part of the study was undertaken to cover the stent with a fragment of the autologous vein. Results in five aneurysms, evaluated three and eight weeks after treatment, showed partial or total repermeabilization of the aneurysms. In the third part of the study, we associated stents and detachable coils. Twelve aneurysms of the carotid artery in pigs were thrombosed and two aneurysms were completely occluded after stent implantation. In the nine other cases, the aneurysms were completely occluded after stent implantation. In the nine other cases, the aneurysms remained patent despite the stent and treatment was then completed with a coil. Six of the animals have been followed for thirteen weeks. One carotid artery thrombosed. In the five other cases, the carotid arteries were patent and the aneurysms were occluded at the control angiogram. Histology results showed the presence of a fibromuscular endothelialized neointima at the neck of the aneurysm in four of the five cases. The technique described here could be proposed for the treatment of wide-neck aneurysms implanted low on the carotid artery in man. Improvements should render the system more flexible.
Similar articles
-
Beta radiation and inhibition of recanalization after coil embolization of canine arteries and experimental aneurysms: how should radiation be delivered?Stroke. 2003 May;34(5):1262-8. doi: 10.1161/01.STR.0000069014.84151.85. Epub 2003 Apr 17. Stroke. 2003. PMID: 12702839
-
Combined stent implantation and endosaccular coil placement for treatment of experimental wide-necked aneurysms: a feasibility study in swine.AJNR Am J Neuroradiol. 1994 Jun;15(6):1087-90. AJNR Am J Neuroradiol. 1994. PMID: 8073977 Free PMC article.
-
The effects of stenting and endothelial denudation on aneurysm and branch occlusion in experimental aneurysm models.J Vasc Surg. 2007 Jun;45(6):1228-35. doi: 10.1016/j.jvs.2007.02.060. J Vasc Surg. 2007. PMID: 17543687
-
Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery. Case report and review of the literature.J Neurosurg. 1997 Dec;87(6):944-9. doi: 10.3171/jns.1997.87.6.0944. J Neurosurg. 1997. PMID: 9384409 Review.
-
Management of Arterial Pseudoaneurysms of the Neck in a Pediatric Population: An Endovascular Case Series and Review of Literature.World Neurosurg. 2019 May;125:e273-e281. doi: 10.1016/j.wneu.2019.01.061. Epub 2019 Jan 24. World Neurosurg. 2019. PMID: 30684708
Cited by
-
Stent-assisted coiling of bifurcation aneurysms may improve endovascular treatment: a critical evaluation in an experimental model.AJNR Am J Neuroradiol. 2013 Mar;34(3):570-6. doi: 10.3174/ajnr.A3231. Epub 2012 Aug 16. AJNR Am J Neuroradiol. 2013. PMID: 22899786 Free PMC article. Clinical Trial.
-
Cyanoacrylate embolization of experimental aneurysms.AJNR Am J Neuroradiol. 2002 Jan;23(1):129-38. AJNR Am J Neuroradiol. 2002. PMID: 11827885 Free PMC article.
-
Endovascular treatment of a ruptured paraclinoid aneurysm of the carotid syphon achieved using endovascular stent and endosaccular coil placement.AJNR Am J Neuroradiol. 2000 Apr;21(4):753-6. AJNR Am J Neuroradiol. 2000. PMID: 10782790 Free PMC article.
MeSH terms
LinkOut - more resources
Medical