Multireader, multimodality receiver operating characteristic curve studies: hypothesis testing and sample size estimation using an analysis of variance approach with dependent observations
- PMID: 9419702
Multireader, multimodality receiver operating characteristic curve studies: hypothesis testing and sample size estimation using an analysis of variance approach with dependent observations
Similar articles
-
Random-effects models in the receiver operating characteristic curve-based assessment of the effectiveness of diagnostic imaging technology: concepts, approaches, and issues.Acad Radiol. 1995 Mar;2 Suppl 1:S4-13; discussion S57-60, S68-9 pas. Acad Radiol. 1995. PMID: 9419700 No abstract available.
-
Regression analysis of correlated receiver operating characteristic data.Acad Radiol. 1995 Mar;2 Suppl 1:S30-6; discussion S61-4, S70-1 pass. Acad Radiol. 1995. PMID: 9419703 No abstract available.
-
A permutation test for comparing ROC curves in multireader studies a multi-reader ROC, permutation test.Acad Radiol. 2006 Apr;13(4):414-20. doi: 10.1016/j.acra.2005.12.012. Acad Radiol. 2006. PMID: 16554220
-
Receiver operating characteristic analysis: a tool for the quantitative evaluation of observer performance and imaging systems.J Am Coll Radiol. 2006 Jun;3(6):413-22. doi: 10.1016/j.jacr.2006.02.021. J Am Coll Radiol. 2006. PMID: 17412096 Review.
-
Assessment of medical imaging systems and computer aids: a tutorial review.Acad Radiol. 2007 Jun;14(6):723-48. doi: 10.1016/j.acra.2007.03.001. Acad Radiol. 2007. PMID: 17502262 Review.
Cited by
-
Promoting the use of the PI-QUAL score for prostate MRI quality: results from the ESOR Nicholas Gourtsoyiannis teaching fellowship.Eur Radiol. 2023 Jan;33(1):461-471. doi: 10.1007/s00330-022-08947-5. Epub 2022 Jun 30. Eur Radiol. 2023. PMID: 35771247 Free PMC article.
-
Power estimation for multireader ROC methods an updated and unified approach.Acad Radiol. 2011 Feb;18(2):129-42. doi: 10.1016/j.acra.2010.09.007. Acad Radiol. 2011. PMID: 21232681 Free PMC article.
-
Perceived sufficiency of full-field digital mammograms with and without irreversible image data compression for comparison with next-year mammograms.J Digit Imaging. 2011 Feb;24(1):66-74. doi: 10.1007/s10278-010-9277-6. J Digit Imaging. 2011. PMID: 20162439 Free PMC article.
-
Evaluation of computer-aided detection and diagnosis systems.Med Phys. 2013 Aug;40(8):087001. doi: 10.1118/1.4816310. Med Phys. 2013. PMID: 23927365 Free PMC article.
-
Power calculation for comparing diagnostic accuracies in a multi-reader, multi-test design.Biometrics. 2014 Dec;70(4):1033-41. doi: 10.1111/biom.12240. Epub 2014 Oct 29. Biometrics. 2014. PMID: 25355470 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical