Multiheaded rotating gamma cameras in cardiac single-photon emission computed tomographic imaging
- PMID: 9420712
- DOI: 10.1007/BF02940343
Multiheaded rotating gamma cameras in cardiac single-photon emission computed tomographic imaging
Abstract
Multiheaded rotating gamma cameras can do more than simply decrease the time required for cardiac single-photon emission computed tomographic (SPECT) acquisitions. They give their users a flexibility to improve image quality that cannot be achieved so easily with single-headed systems. Multiheaded cameras can be used to acquire quickly those radiopharmaceuticals whose distributions washout very rapidly, increase count levels in noisy images without lengthening imaging time, permit high-resolution collimation or electrocardiographic gating with little or no decrease in counts, or acquire transmission images for attenuation correction concurrently with an emission study. This new generation of SPECT scanners gives the nuclear cardiology community a unique opportunity to create a new generation of cardiac SPECT images.
Similar articles
-
Evaluation of a multicrystal gamma camera and rotating chair for tomographic studies of the heart.J Nucl Cardiol. 1996 Jul-Aug;3(4):327-33. doi: 10.1016/s1071-3581(96)90093-8. J Nucl Cardiol. 1996. PMID: 8799252
-
State of the art in emission tomography equipment.Radiographics. 1996 Mar;16(2):409-20. doi: 10.1148/radiographics.16.2.8966297. Radiographics. 1996. PMID: 8966297
-
Application of convergent-beam collimation and simultaneous transmission emission tomography to cardiac single-photon emission computed tomography.Semin Nucl Med. 1994 Jan;24(1):17-37. doi: 10.1016/s0001-2998(05)80247-8. Semin Nucl Med. 1994. PMID: 8122126 Review.
-
Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments.Med Phys. 2016 Jan;43(1):44. doi: 10.1118/1.4937601. Med Phys. 2016. PMID: 26745898
-
Traditional gamma cameras are preferred.J Nucl Cardiol. 2016 Aug;23(4):795-802. doi: 10.1007/s12350-016-0460-0. Epub 2016 Apr 12. J Nucl Cardiol. 2016. PMID: 27072004 Review.
Cited by
-
Comparison between 360 degrees and 180 degrees data sampling in thallium-201 rest-redistribution single-photon emission tomography to predict functional recovery after revascularization.Eur J Nucl Med. 1997 May;24(5):516-22. doi: 10.1007/BF01267683. Eur J Nucl Med. 1997. PMID: 9142732
-
Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps.J Nucl Cardiol. 1995 Nov-Dec;2(6):513-24. doi: 10.1016/s1071-3581(05)80044-3. J Nucl Cardiol. 1995. PMID: 9420834 Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources