Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1994 Jul-Aug;1(4):372-81.
doi: 10.1007/BF02939958.

Incremental diagnostic value of dipyridamole echocardiography and exercise thallium 201 scintigraphy in the assessment of presence and extent of coronary artery disease

Affiliations

Incremental diagnostic value of dipyridamole echocardiography and exercise thallium 201 scintigraphy in the assessment of presence and extent of coronary artery disease

V Di Bello et al. J Nucl Cardiol. 1994 Jul-Aug.

Abstract

Background: The incremental diagnostic information of two noninvasive tests for the detection of coronary artery disease (CAD), dipyridamole echocardiography, and exercise 201Tl myocardial scintigraphy was assessed in a series of 102 patients with ordered logistic regression and receiver-operating characteristic curves.

Methods and results: Patients were selected from those referred to our cardiovascular centers with the clinical suspicion of CAD. After clinical evaluation, all patients underwent both noninvasive tests during hospitalization 2 weeks before coronary arteriography. The coronary arteriogram was used as a gold standard: CAD was defined as the presence of one or more vessels with 50% or greater narrowing of the luminal diameter. Clinical data were 73.0% +/- 5.7% accurate in the prediction of CAD. The addition of dipyridamole echocardiographic data to the clinical model yielded a diagnostic accuracy of 88.3% +/- 4.3% (p < 0.00001), whereas the addition of thallium scintigraphic parameters to the clinical model improved diagnostic accuracy to 93.8% +/- 2.6% (p < 0.00001). A significant increase in accuracy to 97.2% +/- 1.4% was achieved when thallium scintigraphic data were added to the clinical and dipyridamole-echocardiographic model (p < 0.00001).

Conclusion: Both noninvasive methods for detection of CAD, DET, and ETS showed a good diagnostic accuracy especially when tests-derived parameters were combined with clinical data by means of relative logistic models; nevertheless the ETS model showed a higher sensitivity in comparison with the DET model, essentially in presence of a lower extent of CAD.