Technetium 94m-labeled methoxyisobutyl isonitrile: dosimetry and resting cardiac imaging with positron emission tomography
- PMID: 9420726
- DOI: 10.1007/BF02961596
Technetium 94m-labeled methoxyisobutyl isonitrile: dosimetry and resting cardiac imaging with positron emission tomography
Abstract
Background: Development of a positron-emitting form of technetium has allowed the imaging of technetium radiopharmaceuticals with positron emission tomography (PET). We used 94mTc to compare the distribution of the myocardial perfusion agent sestamibi at rest with the conventional PET perfusion tracer 13N-labeled ammonia (13N-ammonia).
Methods and results: Dosimetry calculations were performed with the known whole-body distribution of 99mTc-labeled sestamibi. Dynamic PET imaging of 13N-ammonia and 94mTc-labeled sestamibi (94mTc-sestamibi) for 32 minutes was performed in eight patients with previous myocardial infarction. Initial myocardial and extramyocardial distribution of 94mTc-sestamibi was compared with that of 13N-ammonia by qualitative and quantitative analysis. Quantitative comparison of the two tracers was performed with region-of-interest analysis and circumferential profiles. Qualitatively, the cardiac distribution of the tracers was similar in normal and infarcted myocardium. A decrease in the definition of the epicardial and endocardial borders of the heart was seen with 94mTc-sestamibi, presumably because of the lower dose of radionuclide injected. Quantitatively, there was no difference in infarct size, defined prospectively as tracer activity less than 20% of maximum activity for the section, between the two tracers. Circumferential profile analysis with 12-degree radial sections similarly demonstrated no difference in regional cardiac distribution of the tracers.
Conclusions: These results revealed no significant difference in myocardial uptake compared with 13N-ammonia suggesting that the myocardial uptake of sestamibi correlates with that of myocardial perfusion.
Similar articles
-
Evaluation of regional myocardial perfusion in patients with severe left ventricular dysfunction: comparison of 13N-ammonia PET and 99mTc sestamibi SPECT.J Nucl Cardiol. 1998 Jan-Feb;5(1):4-13. doi: 10.1016/s1071-3581(98)80004-4. J Nucl Cardiol. 1998. PMID: 9504867 Clinical Trial.
-
Positron emission tomography detects evidence of viability in rest technetium-99m sestamibi defects.J Am Coll Cardiol. 1994 Jan;23(1):92-8. doi: 10.1016/0735-1097(94)90506-1. J Am Coll Cardiol. 1994. PMID: 8277101
-
Technetium-94m-teboroxime: synthesis, dosimetry and initial PET imaging studies.J Nucl Med. 1993 Jul;34(7):1058-66. J Nucl Med. 1993. PMID: 8315479
-
The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime.Circulation. 1991 Sep;84(3 Suppl):I7-21. Circulation. 1991. PMID: 1832100 Review.
-
Myocardial perfusion imaging with technetium-99m-labeled agents.Am J Cardiol. 1991 May 21;67(14):27D-34D. doi: 10.1016/s0002-9149(05)80005-0. Am J Cardiol. 1991. PMID: 1827941 Review.
Cited by
-
Expanding the PET radioisotope universe utilizing solid targets on small medical cyclotrons.RSC Adv. 2021 Sep 21;11(49):31098-31123. doi: 10.1039/d1ra04480j. eCollection 2021 Sep 14. RSC Adv. 2021. PMID: 35498914 Free PMC article. Review.
-
What is the current status of quantification and nuclear medicine in cardiology?Eur J Nucl Med. 1996 Jul;23(7):815-51. doi: 10.1007/BF00843713. Eur J Nucl Med. 1996. PMID: 8662122 Review. No abstract available.
-
Planar and SPECT imaging in the era of PET and PET-CT: can it survive the test of time?Eur J Nucl Med Mol Imaging. 2008 Aug;35(8):1554-9. doi: 10.1007/s00259-008-0813-2. Eur J Nucl Med Mol Imaging. 2008. PMID: 18594816 No abstract available.
-
Technetium 99m-labeled teboroxime: death in utero, infanticide, or failure to thrive?J Nucl Cardiol. 1995 Jan-Feb;2(1):88-91. doi: 10.1016/s1071-3581(05)80016-9. J Nucl Cardiol. 1995. PMID: 9420769 No abstract available.
-
Evaluation of regional myocardial perfusion in patients with severe left ventricular dysfunction: comparison of 13N-ammonia PET and 99mTc sestamibi SPECT.J Nucl Cardiol. 1998 Jan-Feb;5(1):4-13. doi: 10.1016/s1071-3581(98)80004-4. J Nucl Cardiol. 1998. PMID: 9504867 Clinical Trial.
References
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical