Myocardial technetium 99m-labeled sestamibi single-photon emission computed tomographic imaging in the detection of coronary artery disease: comparison between early (15 minutes) and delayed (60 minutes) imaging
- PMID: 9420728
- DOI: 10.1007/BF02961598
Myocardial technetium 99m-labeled sestamibi single-photon emission computed tomographic imaging in the detection of coronary artery disease: comparison between early (15 minutes) and delayed (60 minutes) imaging
Abstract
Background: Previous studies have demonstrated that there is a "partial" myocardial redistribution of 99mTc-labeled sestamibi (MIBI) between 1 and 3 hours after intravenous injection at stress. The purpose of this prospective study was to compare MIBI single-photon emission computed tomographic (SPECT) imaging performed 15 and 60 minutes after the injection at stress in the detection of coronary artery disease.
Methods and results: Thirty-five patients with coronary artery disease (26 underwent coronary angiography and 23 had a positive 201Tl study result) were included in this study. SPECT imaging started 15 minutes after the injection of 25 to 30 mCi MIBI at peak stress (180-degree arc, 32 angles, 25 sec/view, and high-resolution collimator). Patients underwent reimaging at 60 minutes according to the same protocol and with the same gamma camera. A rest study was obtained 75 minutes after the injection of MIBI (25 to 30 mCi) at rest, 48 hours later. Images (divided for a total of 19 segments per patient) were interpreted by two blinded observers for patient diagnosis and segmental comparison. The patient diagnosis was the same for the two protocols: normal = 3, ischemia = 27, and scar = 5. The segmental agreement (kappa = 0.90) was 632/665 (95.0%). The imaging performed at 15 minutes detected normal, ischemia, and scar in 413, 189, and 63 segments, respectively, whereas the imaging performed at 60 minutes detected 422, 180, and 63 segments, respectively (difference not significant). The early and delayed images were placed side by side for subjective comparison of the extent of the defect. Early imaging showed slightly larger defects in six patients, equal defects in 24 patients, and slightly smaller defects in five patients. Ischemic/normal wall ratios were 0.67 +/- 0.16 at 15 minutes and 0.68 +/- 0.15 at 60 minutes.
Conclusions: There is no clinically significant difference between SPECT imaging performed at 15 minutes or 60 minutes after the injection of MIBI at stress. Furthermore, this study showed that it is feasible to obtain good-quality MIBI images even 15 minutes after the injection at stress.
Similar articles
-
Comparison of rest thallium-201 imaging and rest technetium-99m sestamibi imaging for assessment of myocardial viability in patients with coronary artery disease and severe left ventricular dysfunction.J Am Coll Cardiol. 1996 Jun;27(7):1592-7. doi: 10.1016/0735-1097(96)00090-3. J Am Coll Cardiol. 1996. PMID: 8636541 Clinical Trial.
-
Evaluation of myocardial ischemia using a rest metabolism/stress perfusion protocol with fluorine-18 deoxyglucose/technetium-99m MIBI and dual-isotope simultaneous-acquisition single-photon emission computed tomography.J Am Coll Cardiol. 1995 Oct;26(4):870-8. doi: 10.1016/0735-1097(95)00295-6. J Am Coll Cardiol. 1995. PMID: 7560611
-
Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability.Nucl Med Commun. 2003 Mar;24(3):251-7. doi: 10.1097/00006231-200303000-00004. Nucl Med Commun. 2003. PMID: 12612465
-
Dipyridamole stress echocardiography and ultrasonic myocardial tissue characterization in predicting myocardial ischemia, in comparison with dipyridamole stress Tc-99m MIBI SPECT myocardial imaging.Jpn Heart J. 2004 Nov;45(6):937-48. doi: 10.1536/jhj.45.937. Jpn Heart J. 2004. PMID: 15655269
-
Initial and delayed stress phase imaging in a single-injection double-acquisition SPECT. The potential value of early 99mTc-MIBI redistribution in assessment of myocardial perfusion reversibility in patients with coronary artery disease.Nuklearmedizin. 2010;49(1):19-27. doi: 10.3413/nukmed-0266. Nuklearmedizin. 2010. PMID: 20162245 Clinical Trial.
Cited by
-
Should early post-stress imaging be performed on a routine clinical basis for myocardial perfusion studies?J Nucl Cardiol. 2014 Dec;21(6):1177-80. doi: 10.1007/s12350-014-9972-7. Epub 2014 Sep 12. J Nucl Cardiol. 2014. PMID: 25213202 No abstract available.
-
Technetium-99m-sestamibi redistribution after exercise stress test identified by a novel cardiac gamma camera: two case reports.Clin Cardiol. 2010 Apr;33(4):E39-45. doi: 10.1002/clc.20519. Clin Cardiol. 2010. PMID: 20358533 Free PMC article.
-
Myocardial uptake of thallium 201 and technetium 99m-labeled sestamibi after ischemia and reperfusion: comparison by quantitative dual-tracer autoradiography in rabbits.J Nucl Cardiol. 1994 Jul-Aug;1(4):351-64. doi: 10.1007/BF02939956. J Nucl Cardiol. 1994. PMID: 9420718
-
Choosing a thallium-201 or technetium 99m sestamibi imaging protocol.J Nucl Cardiol. 1994 Sep-Oct;1(5 Pt 2):S99-108. doi: 10.1007/BF03032555. J Nucl Cardiol. 1994. PMID: 9420735 Review.
-
Validation of early image acquisitions following Tc-99 m sestamibi injection using a semiconductors camera of cadmium-zinc-telluride.J Nucl Cardiol. 2017 Aug;24(4):1149-1156. doi: 10.1007/s12350-016-0499-y. Epub 2016 Apr 20. J Nucl Cardiol. 2017. PMID: 27098337
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources