Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps
- PMID: 9420834
- DOI: 10.1016/s1071-3581(05)80044-3
Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps
Abstract
Attenuation is believed to be one of the major causes of false-positive cardiac single-photon emission computed tomographic (SPECT) perfusion images. This article reviews the physics of attenuation, the artifacts produced by attenuation, and the need for scatter correction in combination with attenuation correction. The review continues with a comparison of the various configurations for transmission imaging that could be used to estimate patient specific attenuation maps, and an overview of how these are being developed for use on multiheaded SPECT systems, including discussions of truncation, noise, and spatial resolution of the estimated attenuation maps. Ways of estimating patient specific attenuation maps besides transmission imaging are also discussed.
Similar articles
-
Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms.J Nucl Cardiol. 1996 Jan-Feb;3(1):55-64. doi: 10.1016/s1071-3581(96)90024-0. J Nucl Cardiol. 1996. PMID: 8799228 Review.
-
Estimation of attenuation maps from scatter and photopeak window single photon-emission computed tomographic images of technetium 99m-labeled sestamibi.J Nucl Cardiol. 1997 Jan-Feb;4(1 Pt 1):42-51. doi: 10.1016/s1071-3581(97)90048-9. J Nucl Cardiol. 1997. PMID: 9138839
-
Influence of photon scattering and attenuation on ROI analysis in brain perfusion single-photon emission tomographic imaging of normal subjects.Ann Nucl Med. 2005 Oct;19(7):567-72. doi: 10.1007/BF02985049. Ann Nucl Med. 2005. PMID: 16363621 Clinical Trial.
-
Problems created in attenuation-corrected SPECT images by artifacts in attenuation maps: a simulation study.J Nucl Med. 2005 Feb;46(2):335-43. J Nucl Med. 2005. PMID: 15695795
-
Multiheaded rotating gamma cameras in cardiac single-photon emission computed tomographic imaging.J Nucl Cardiol. 1994 May-Jun;1(3):292-303. doi: 10.1007/BF02940343. J Nucl Cardiol. 1994. PMID: 9420712 Review.
Cited by
-
An introduction to attenuation correction.J Nucl Cardiol. 1999 Jul-Aug;6(4):449-57. doi: 10.1016/s1071-3581(99)90011-9. J Nucl Cardiol. 1999. PMID: 10461612 Review.
-
Does scatter correction of cardiac SPECT improve image quality in the presence of high extracardiac activity?J Nucl Cardiol. 2004 Jul-Aug;11(4):424-32. doi: 10.1016/j.nuclcard.2004.03.031. J Nucl Cardiol. 2004. PMID: 15295411
-
Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT.Eur J Nucl Med Mol Imaging. 2008 Jun;35(6):1117-23. doi: 10.1007/s00259-008-0718-0. Epub 2008 Jan 25. Eur J Nucl Med Mol Imaging. 2008. PMID: 18219483
-
SPECT/CT: an update on technological developments and clinical applications.Br J Radiol. 2018 Jan;91(1081):20160402. doi: 10.1259/bjr.20160402. Epub 2017 Jan 16. Br J Radiol. 2018. PMID: 27845567 Free PMC article. Review.
-
Comparison of pharmacologic stress agents.J Nucl Cardiol. 1996 Nov-Dec;3(6 Pt 2):S22-6. doi: 10.1016/s1071-3581(96)90204-4. J Nucl Cardiol. 1996. PMID: 8989683 Review.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Other Literature Sources