Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1997 Dec;38(12):1847-56.

Flow versus uptake comparisons of thallium-201 with technetium-99m perfusion tracers in a canine model of myocardial ischemia

Affiliations
  • PMID: 9430457
Free article
Comparative Study

Flow versus uptake comparisons of thallium-201 with technetium-99m perfusion tracers in a canine model of myocardial ischemia

M J Meleca et al. J Nucl Med. 1997 Dec.
Free article

Abstract

We investigated the myocardial flow kinetics of six putative radioperfusion agents (99mTc-Q3, 99mTc-Q4, 99mTc-Q12, 99mTc-sestamibi, 99mTc-tetrofosmin and 99mTcN-NOET) and 201Tl in a canine model of myocardial ischemia with pharmacologic coronary artery vasodilation.

Methods: In 31 open-chest dogs with acute coronary occlusion, dipyridamole (approximately 0.56 mg/kg) was infused intravenously, followed by a perfusion tracer injection and radioactive microspheres for myocardial blood flow (MBF) measurement. The paired data were normalized using three techniques; average, normal or maximum myocardial tracer activity and MBF.

Results: The upper limit of MBF obtained for the group of tracers ranged from 4.2 ml/min/g to 8.2 ml/min/g. There was a statistically significant (p < 0.0001) linear correlation (r = 0.87-0.98) between the normalized myocardial activity and the normalized MBF values of each of the tracers. The slope of the curve normalized by average for 201Tl (0.83) was greater than those for the 99mTc tracers, and the intercept (0.07) was lower than those for the 99mTc tracers. Slopes and intercepts for the 99mTc agents were as follows: 99mTc-Q3, 0.81 and 0.18; 99mTc-Q4, 0.61 and 0.41; 99mTc-Q12, 0.63 and 0.39; 99mTc-sestamibi, 0.62 and 0.34; 99mTc-tetrofosmin, 0.68 and 0.32; and 99mTcN-NOET, 0.71 and 0.29, respectively.

Conclusion: In an anesthetized open-chest canine model of regional myocardial ischemia with dipyridamole induced hyperemia, 201Tl shows a more ideal relationship between tracer uptake and MBF than do the 99mTc-based agents. Of the various 99mTc-based imaging agents studied, the myocardial flow kinetics of 99mTc-Q3 appear to be closest to ideal. This relationship is maintained regardless of the normalization technique used. This may, in theory, imply a higher sensitivity in discerning ischemic from normal myocardium and a role in diagnostic nuclear imaging for 99mTc-Q3.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources