Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Dec;64(6):1757-62; discussion 1762-3.
doi: 10.1016/s0003-4975(97)01107-7.

Improved results for postcardiotomy cardiogenic shock with the use of implantable left ventricular assist devices

Affiliations

Improved results for postcardiotomy cardiogenic shock with the use of implantable left ventricular assist devices

J J DeRose Jr et al. Ann Thorac Surg. 1997 Dec.

Abstract

Background: Over the past decade, the use of mechanical circulatory support in patients with postcardiotomy cardiogenic shock has resulted in hospital discharge rates of 25% to 40%. In an attempt to improve patient survival, we initiated a program of early insertion of an implantable Thermocardiosystems Incorporated Heartmate left ventricular assist device in patients who have circulatory failure after having undergone high-risk cardiac operations.

Methods: Between April 1993 and February 1997, 12 patients underwent insertion of an implantable left ventricular assist device for postcardiotomy cardiogenic shock after coronary artery bypass grafting. Indications for insertion included postoperative cardiogenic shock (7 patients), postoperative cardiac arrest (3 patients), and failure to wean from cardiopulmonary bypass (2 patients).

Results: The median time to device insertion was 3.5 days. The mean duration of left ventricular assist device support was 103 +/- 19 days (range, 2 to 225 days). Nine of 11 patients (82%) survived to undergo either transplantation (8 patients) or explantation (1 patient), with successful hospital discharge of all 9 patients. The major complication was device-related infection (42%). A single thromboembolism occurred in a patient with an infection.

Conclusions: Long-term outcome after postcardiotomy cardiogenic shock is improved substantially with the use of an implantable left ventricular assist device early in the postoperative course. Access to such a device is an important consideration before undertaking a high-risk cardiac operation, and early implantation of the device is a critical factor in ensuring long-term survival.

PubMed Disclaimer

LinkOut - more resources