. 1998 Jan;133(1):45-9.
doi: 10.1001/archsurg.133.1.45.

Morbidity and mortality of reconstructive surgery of noninfected false aneurysms detected long after aortic prosthetic reconstruction

Affiliations

Morbidity and mortality of reconstructive surgery of noninfected false aneurysms detected long after aortic prosthetic reconstruction

E J Mulder et al. Arch Surg. 1998 Jan.

Abstract

Objective: To determine the morbidity and mortality of surgical treatment of false (anastomotic) aneurysms, we analyzed the results of 158 consecutive surgical procedures for repair of false aneurysms that were detected as a result of a surveillance program after aortic reconstruction with a prosthesis.

Design: Retrospective analysis of patient data from a vascular registry that included information on the long-term follow-up of our patients.

Setting: A university hospital (tertiary referral center) in the Netherlands that has been performing vascular reconstructive surgery since 1958.

Patients: We performed 158 surgical procedures on 135 patients with 220 noninfected false aneurysms. Using a yearly surveillance program, the false aneurysms were detected at a mean interval of 8 years after the initial reconstruction. Most patients (60%) were asymptomatic. The operation was performed as an emergency in 25 instances (16%).

Results: The mortality rate of patients receiving nonsurgical treatment was very high (61%) owing to documented rupture (11 of 18 patients). The intraoperative death rate was 7.6% per procedure. This was higher for emergency (24%) than for elective procedures (4.5%).

Conclusions: Conservative follow-up carries a very high mortality rate, as does emergency surgery for a false aneurysm. However, the intraoperative mortality rate of elective reconstruction of a false aneurysm can be in the same range as that of elective primary aortic reconstruction. Therefore, we advocate a surveillance program, including yearly ultrasound studies, after prosthetic aortic reconstruction for the timely detection and elective repair of all false aneurysms.