Characteristics of metals used in implants
- PMID: 9440845
- DOI: 10.1089/end.1997.11.383
Characteristics of metals used in implants
Abstract
The performance of any material in the human body is controlled by two sets of characteristics: biofunctionality and biocompatibility. With the wide range of materials available in the mid-1990s, it is relatively easy to satisfy the requirements for mechanical and physical functionality of implantable devices. Therefore, the selection of materials for medical applications is usually based on considerations of biocompatibility. When metals and alloys are considered, the susceptibility of the material to corrosion and the effect the corrosion has on the tissue are the central aspects of biocompatibility. Corrosion resistance of the currently used 316L stainless steel, cobalt-chromium, and titanium-based implant alloys relies on their passivation by a thin surface layer of oxide. Stainless steel is the least corrosion resistant, and it is used for temporary implants only. The titanium and Co-Cr alloys do not corrode in the body; however, metal ions slowly diffuse through the oxide layer and accumulate in the tissue. When a metal implant is placed in the human body, it becomes surrounded by a layer of fibrous tissue of a thickness that is proportional to the amount and toxicity of the dissolution products and to the amount of motion between the implant and the adjacent tissues. Pure titanium may elicit a minimal fibrous encapsulation under some conditions, whereas the proliferation of a fibrous layer as much as 2 mm thick is encountered with the use of stainless steel implants. Superior fracture and fatigue resistance have made metals the materials of choice for traditional load-bearing applications. In this review, the functionality of currently used metals and alloys is discussed with respect to stenting applications. In addition, the "shape memory" and "pseudo-elasticity" properties of Nitinol-an alloy that is being considered for the manufacturing of urologic stents-are described.
Similar articles
-
Biomaterial optimization in total disc arthroplasty.Spine (Phila Pa 1976). 2003 Oct 15;28(20):S139-52. doi: 10.1097/01.BRS.0000092214.87225.80. Spine (Phila Pa 1976). 2003. PMID: 14560185
-
Corrosion and surface modification on biocompatible metals: A review.Mater Sci Eng C Mater Biol Appl. 2017 Aug 1;77:1261-1274. doi: 10.1016/j.msec.2017.04.102. Epub 2017 Apr 20. Mater Sci Eng C Mater Biol Appl. 2017. PMID: 28532004 Review.
-
Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.J Biomed Mater Res A. 2007 Aug;82(2):403-14. doi: 10.1002/jbm.a.31154. J Biomed Mater Res A. 2007. PMID: 17295246
-
[Biodeterioration and corrosion of metallic implants and prostheses].Medicina (B Aires). 1993;53(3):260-74. Medicina (B Aires). 1993. PMID: 8114635 Review. Spanish.
-
Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?Spine J. 2004 Jul-Aug;4(4):379-87. doi: 10.1016/j.spinee.2003.12.004. Spine J. 2004. PMID: 15246296
Cited by
-
Biomimetic CaP coating incorporated with parathyroid hormone improves the osseointegration of titanium implant.J Mater Sci Mater Med. 2012 Sep;23(9):2177-86. doi: 10.1007/s10856-012-4682-7. Epub 2012 May 26. J Mater Sci Mater Med. 2012. PMID: 22639151
-
Endothelial Cell Responses to a Highly Deformable Titanium Alloy Designed for Vascular Stent Applications.J Funct Biomater. 2021 May 14;12(2):33. doi: 10.3390/jfb12020033. J Funct Biomater. 2021. PMID: 34068852 Free PMC article.
-
Recovery of motor deficit, cerebellar serotonin and lipid peroxidation levels in the cortex of injured rats.Neurochem Res. 2010 Oct;35(10):1538-45. doi: 10.1007/s11064-010-0213-4. Epub 2010 Jun 10. Neurochem Res. 2010. PMID: 20535555
-
Effect of cobalt addition on the corrosion behavior of near equiatomic NiTi shape memory alloy in normal saline solution: electrochemical and XPS studies.RSC Adv. 2018 May 24;8(34):19289-19300. doi: 10.1039/c8ra02031k. eCollection 2018 May 22. RSC Adv. 2018. PMID: 35539683 Free PMC article.
-
Customized Additive Manufacturing in Bone Scaffolds-The Gateway to Precise Bone Defect Treatment.Research (Wash D C). 2023 Oct 9;6:0239. doi: 10.34133/research.0239. eCollection 2023. Research (Wash D C). 2023. PMID: 37818034 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources