Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1997 Dec;13(6):731-6.
doi: 10.1016/s0749-8063(97)90008-6.

Load to failure of common meniscal repair techniques: effects of suture technique and suture material

Affiliations
Comparative Study

Load to failure of common meniscal repair techniques: effects of suture technique and suture material

W R Post et al. Arthroscopy. 1997 Dec.

Abstract

Success of meniscal repair with early or immediate motion depends on the ability of the suture fixation to withstand the loads applied. Vertical and horizontal mattress suture techniques were tested using 2-0 Ethibond, and 0-PDS and 1-PDS sutures (Ethicon, Somerville, NJ). Mulberry knot technique was tested with 0-PDS and 1-PDS sutures. Twenty menisci (60 sutures) were tested for each suture material. Sutures were placed 3 to 4 mm from the peripheral edge of the meniscus with double barreled cannulas for vertical and horizontal mattress techniques or a spinal needle for the mulberry knot technique, reproducing clinical techniques of meniscal repair. Mechanical testing of suture fixation was performed to failure at a rate of 10 mm/min on a MTS material testing system (MTS Systems Corp, Minneapolis, MN). Suture pullouts were reported as the load displacement to failure from the inner fragment only, because clinical failure would ensue should a suture pull through the inner fragment of a tear. Vertical mattress technique with 1-PDS suture had significantly greater load to failure than any other combination (P < .05). Analysis of variance showed that the vertical mattress technique had statistically superior pullout strength (P < .0001) compared with the horizontal mattress and mulberry knot techniques, which were statistically similar. There were significant differences (P < .0001) between suture types, with 1-PDS proving best compared with 0-PDS, which was stronger than 2-0 Ethibond. Selection of suture material had the greatest impact on vertical mattress load to failure and was not important to the strength of the other techniques.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources